Prostate Imaging Reporting and Data System Version 2.1: 2019 Update of Prostate Imaging Reporting and Data System Version 2
- PMID: 30898406
- DOI: 10.1016/j.eururo.2019.02.033
Prostate Imaging Reporting and Data System Version 2.1: 2019 Update of Prostate Imaging Reporting and Data System Version 2
Abstract
The Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) was developed with a consensus-based process using a combination of published data, and expert observations and opinions. In the short time since its release, numerous studies have validated the value of PI-RADS v2 but, as expected, have also identified a number of ambiguities and limitations, some of which have been documented in the literature with potential solutions offered. To address these issues, the PI-RADS Steering Committee, again using a consensus-based process, has recommended several modifications to PI-RADS v2, maintaining the framework of assigning scores to individual sequences and using these scores to derive an overall assessment category. This updated version, described in this article, is termed PI-RADS v2.1. It is anticipated that the adoption of these PI-RADS v2.1 modifications will improve inter-reader variability and simplify PI-RADS assessment of prostate magnetic resonance imaging even further. Research on the value and limitations on all components of PI-RADS v2.1 is strongly encouraged.
Keywords: Prostate Imaging Reporting and Data System Version 2; Prostate Imaging Reporting and Data System Version 2.1; Prostate cancer.
Published by Elsevier B.V.
Comment in
-
Reply to Byung Kwan Park's Letter to the Editor re: Baris Turkbey, Andrew B. Rosenkrantz, Masoom A. Haider, et al. Prostate Imaging Reporting and Data System Version 2.1: 2019 Update of Prostate Imaging Reporting and Data System Version 2. Eur Urol 2019;76:329-40.Eur Urol. 2019 Sep;76(3):e79. doi: 10.1016/j.eururo.2019.05.039. Epub 2019 Jun 8. Eur Urol. 2019. PMID: 31182228 No abstract available.
-
Re: Baris Turkbey, Andrew B. Rosenkrantz, Masoom A. Haider, et al. Prostate Imaging Reporting and Data System Version 2.1: 2019 Update of Prostate Imaging Reporting and Data System Version 2. Eur Urol 2019;76:340-51.Eur Urol. 2019 Sep;76(3):e78. doi: 10.1016/j.eururo.2019.05.038. Epub 2019 Jun 8. Eur Urol. 2019. PMID: 31186172 No abstract available.
-
Biparametric MRI with simplified PI-RADS (S-PI-RADS) for prostate cancer detection and management: what do radiologist need to know.Radiol Med. 2021 Dec;126(12):1660-1661. doi: 10.1007/s11547-021-01343-x. Epub 2021 Dec 17. Radiol Med. 2021. PMID: 34919192 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous