. 2019 May;68(5):309-316.
doi: 10.1007/s00101-019-0579-x.

[Catheterization of the subclavian vein and the risk of pneumothorax : Mechanical ventilation increases the risk of pneumothorax during infraclavicular landmark-guided subclavian vein puncture: a prospective randomized study]

[Article in German]
Affiliations

[Catheterization of the subclavian vein and the risk of pneumothorax : Mechanical ventilation increases the risk of pneumothorax during infraclavicular landmark-guided subclavian vein puncture: a prospective randomized study]

[Article in German]
T Palmaers et al. Anaesthesist. 2019 May.

Erratum in

Abstract

Background: Infraclavicular subclavian vein (SCV) catheterization is a standard procedure in anesthesia and intensive care. There is a lack of evidence on how mechanical ventilation during venipuncture of the SCV influences pneumothorax rates.

Objective: Primary hypothesis: non-inferiority of continuing vs. discontinuing mechanical ventilation during infraclavicular puncture of the SCV with respect to the pneumothorax rate.

Material and methods: This prospective, randomized and single-blinded study was approved by the local ethics committee. A total of 1021 eligible patients who underwent cranial neurosurgery in 2 different university hospitals were assessed between August 2014 and October 2017. Patients were randomly assigned to two groups directly before induction of anesthesia. Intervention groups for venipuncture of the SCV were mechanical ventilation: tidal volume 7 ml/kg ideal body weight, positive end expiratory pressure (PEEP) ideal body weight/10, n = 535, or apnea: manual/spontaneous, APL valve 0 mbar, n = 486. Patients and the physicians who assessed pneumothorax rates were blinded to the intervention group. Venipuncture was carried out by both inexperienced and experienced physicians.

Results: The pneumothorax rate was significantly higher in the mechanical ventilation group (2.2% vs. 0.4%; p = 0.012) with an odds ratio (OR) of 5.63 (95% confidence interval, CI: 1.17-27.2; p = 0.031). A lower body mass index (BMI) was associated with a higher pneumothorax rate, OR 0.89 (95% CI: 0.70-0.96; p = 0.013).

Conclusion: In this study landmark-guided infraclavicular SCV catheterization was associated with a significantly higher rate of pneumothorax when venipuncture was performed during mechanical ventilation and not in apnea. If a short phase of apnea is justifiable in the patient, mechanical ventilation should be discontinued during the venipuncture procedure.

Keywords: Central venous catheter; Complication; Pneumothorax; Subclavian vein.

PubMed Disclaimer

References

    1. Anesthesiology. 2015 Jul;123(1):66-78 - PubMed
    1. Anaesthesiol Intensive Ther. 2013 Apr-Jun;45(2):89-92 - PubMed
    1. Cochrane Database Syst Rev. 2015 Jan 09;1:CD011447 - PubMed
    1. Anesth Analg. 2011 Jun;112(6):1448-51 - PubMed
    1. Acta radiol. 1953 May;39(5):368-76 - PubMed