Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Dec;34(9):1763-1779.
doi: 10.1007/s10103-019-02770-z. Epub 2019 Mar 22.

Laser asymmetric ablation method to improve corneal shape

Affiliations

Laser asymmetric ablation method to improve corneal shape

José Alberto Rodríguez Agudo et al. Lasers Med Sci. 2019 Dec.

Abstract

This study aims to assess whether central-symmetric corneal thickness reduces off-centered corneal shift caused by intraocular pressure (IOP). In this retrospective study, 122 healthy eyes of 62 presbyopic patients, mostly myopic, were divided into two groups. Two distinct asymmetric corneal ablations were applied in peripheral presbyopia correction to produce central-symmetric corneal thickness, which reduces the off-centered corneal shift by utilizing intraocular pressure. The first method used a 90° angled combination in group 1 and the second method used a 45° angled combination in group 2. Target refraction was spherical equivalent of - 1D. Self-developed image processing algorithm analyzed the change in thickness and the posterior cone, and obtained two factors: central symmetry (f) and visual axis deviation (d), from each eye's pre and postoperative maps of Orbscan II. UDVA and UNVA were also analyzed. In both groups, mean SE was about - 1D and there was no significant difference in UDVA. UNVA was better in group 2 than group 1. Only in group 2, corneal thickness and posterior cone became central-symmetric and the posterior corneal apex point relocated towards the visual axis. The p values were 0.03, 0.04, and 0.03, respectively. This is the first study to control corneal shape by utilizing the interaction between intraocular pressure and corneal thickness. Only group 2 was applied with asymmetric corneal ablation created by the 45° angled combination of semi-cylindrical ablation patterns, and intraocular pressure contributed significantly to reduce the off-centered corneal shift and reshaped the posterior corneal cone to the center.

Keywords: Asymmetric corneal ablation; Central-symmetric corneal thickness; Laser asymmetric keratectomy; Semi-cylindrical ablation.

PubMed Disclaimer

References

    1. Clin Exp Ophthalmol. 2010 Mar;38(2):192-210 - PubMed
    1. J Refract Surg. 1998 May-Jun;14(3):312-7 - PubMed
    1. J Cataract Refract Surg. 2000 Jun;26(6):867-71 - PubMed
    1. Br J Ophthalmol. 1999 Jul;83(7):774-8 - PubMed
    1. Biophys J. 1998 Nov;75(5):2508-12 - PubMed

LinkOut - more resources