. 2019 Jun;33(3):364-371.
doi: 10.1007/s00540-019-02632-6. Epub 2019 Mar 23.

Accuracy of the ClearSight™ system in patients undergoing abdominal aortic aneurysm surgery

Affiliations

Accuracy of the ClearSight™ system in patients undergoing abdominal aortic aneurysm surgery

Miho Sumiyoshi et al. J Anesth. 2019 Jun.

Abstract

Purpose: The ClearSight™ device monitors continuous pressure and cardiac output via pulse contour analysis. ClearSight™, however, may not be reliable in patients with reduced peripheral perfusion caused by high peripheral resistance. This study aimed to elucidate the accuracy and trending ability of ClearSight™ in patients undergoing abdominal aortic aneurysm (AAA) surgery by comparing the ClearSightTM-derived cardiac index (CICS) with that measured using three-dimensional echocardiography (CI3D).

Methods: The study included 20 patients who underwent elective AAA surgery. CICS and CI3D were measured simultaneously at eight time points during the surgery. Trending ability was investigated after aortic clamping and unclamping. We used CI3D as the reference method.

Results: Bland-Altman analysis showed a wide limit of agreement between CICS and CI3D (percentage error 41.3%). Subgroup analysis showed a lower percentage error (33.2%) in patients with CI ≥ 2.5 L/min/m2. The cubic splines related to the CI3D and CI discrepancy were negatively sloped, indicating that CI3D had significant influence on the CI discrepancy (p < 0.001). Four-quadrant plot analysis showed that the tracking ability of ClearSight™ after aortic clamping and declamping were clinically unacceptable (81.3% and 78.6%, respectively). Also, the polar plot analysis showed that the concordance rate of ClearSight™ after aortic clamping and declamping were clinically unacceptable (58.3% and 66.7%, respectively).

Conclusions: ClearSight™ was not sufficiently accurate in patients undergoing AAA surgery. The tracking ability of ClearSight™ after aortic clamping was below the acceptable limit.

Keywords: Blood pressure monitor; Cardiac output; ClearSight; Echocardiography; Ultrasound.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Circulation. 2000 Jun 27;101(25):2922-7 - PubMed
    1. J Am Soc Echocardiogr. 2003 Jul;16(7):777-802 - PubMed
    1. J Am Coll Cardiol. 2004 Aug 18;44(4):878-86 - PubMed
    1. Circulation. 2009 Jan 20;119(2):314-29 - PubMed
    1. JACC Cardiovasc Imaging. 2008 Jul;1(4):413-23 - PubMed

Publication types

LinkOut - more resources