Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2020 Aug;34(8):2197-2204.
doi: 10.1519/JSC.0000000000003119.

Reliability and Validity of a New Portable Tethered Sprint Running Test as a Measure of Maximal Anaerobic Performance

Affiliations
Randomized Controlled Trial

Reliability and Validity of a New Portable Tethered Sprint Running Test as a Measure of Maximal Anaerobic Performance

Mirjam Limmer et al. J Strength Cond Res. 2020 Aug.

Abstract

Limmer, M, Berkholz, A, de Marées, M, and Platen, P. Reliability and validity of a new portable tethered sprint running test as a measure of maximal anaerobic performance. J Strength Cond Res 34(8): 2197-2204, 2020-The purposes of this study were to develop a new portable tethered sprint running (PTSR) test for field-based anaerobic performance testing with restricted spatial conditions and the logistical challenge of carrying test equipment, and to determine reliability of the PTSR test. For validity, performance measures were compared with the cycle ergometer Wingate Anaerobic Test (WAnT) power outputs. Twelve recreationally active men and women (24.3 ± 1.6 years; 1.77 ± 0.07 m; 73.3 ± 12.5 kg) performed one familiarization trial followed by 3 randomly assigned experimental 60-second all-out effort trials consisting of one WAnT and 2 PTSR tests. All trials were performed in a randomized order on different days separated by at least 48 hours. Heart rate (HR) and maximum blood lactate concentration were recorded for each experimental trial to determine the physiological responses to the maximal efforts. Correlation coefficients indicated significant relationships between mean force (MF) and peak force (PF) in the PTSR test and mean power (MP) (r = 0.651, p = 0.022) and peak power (PP) (r = 0.877, p = 0.002) in the WAnT, but not for the fatigue index (r = 0.280, p = 0.379). In addition, both PTSR trials showed no significant differences (p > 0.05) between trials and a high reliability for the performance variables MF (intraclass correlation coefficient [ICC] = 0.98, coefficient of variation [%CV] = 7.7), PF (ICC = 0.98, %CV = 8.4), and HR (ICC = 0.92, %CV = 3.1). In conclusion, our results suggest that despite insufficient stimulation of anaerobic metabolism in some subjects resulting from poor implementation of test instructions, the PTSR is a reliable and valid test for an easy and practical assessment of maximal anaerobic performance under different field conditions.

PubMed Disclaimer

References

    1. Andrade VL, Zagatto AM, Kalva-Filho CA, Mendes OC, Gobatto CA, Campos EZ, et al. Running-based anaerobic sprint test as a procedure to evaluate anaerobic power. Int J Sports Med 36: 1156–1162, 2015.
    1. Atkinson G, Nevill AM. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med 26: 217–238, 1998.
    1. Bar-Or O. The Wingate anaerobic test. Sports Med 4: 381–394, 1987.
    1. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1: 307–310, 1986.
    1. Borg GA. Psychophysical bases of perceived exertion. Med Sci Sports Exerc 14: 377–381, 1982.

Publication types

LinkOut - more resources