Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Jun 27;11(6):440-444.
doi: 10.3855/jidc.7730.

Evaluation of in-house loop-mediated isothermal amplification for tuberculosis diagnosis compared with Xpert MTB/RIF

Affiliations
Free article

Evaluation of in-house loop-mediated isothermal amplification for tuberculosis diagnosis compared with Xpert MTB/RIF

Charity Habeenzu et al. J Infect Dev Ctries. .
Free article

Abstract

Introduction: To evaluate the diagnostic performances of an in-house loop-mediated isothermal amplification (LAMP) kit and the Xpert MTB/RIF test for the diagnosis of pulmonary tuberculosis in a resource-limited setting, this study was performed at the University Teaching Hospital, Ministry of Health, the Republic of Zambia.

Methodology: Two hundred sputum specimens obtained from new tuberculosis (TB) suspects were used for the evaluation of the diagnostic performance of an in-house LAMP kit in comparison with the Xpert MTB/RIF kit.

Results: The sensitivity of in-house LAMP and Xpert MTB/RIF was 96.9% and 95.4% in smear-positive samples, 96.8% and 100% in smear-positive/culture-positive samples, and 39.1% and 73.9% in smear-negative/culture-positive samples, respectively. The specificity of in-house LAMP and MTB/RIF kits with culture was 96.5% and 94.5%, respectively. This indicated the superiority of the Xpert MTB/RIF kit; however, mechanical errors during sample processing and the insufficient quantity of samples by Xpert MTB/RIF kit occurred at 2.0% and 19.7%, respectively, comparing to the 100% accessibility of in-house LAMP.

Conclusions: Considering the results obtained in this study together with the easy setup with much simpler equipment, such as an aluminum heat block or water bath, in in-house LAMP compared with real-time polymerase chain reaction equipment in Xpert MTB/RIF kit, the applicability of in-house LAMP for the screening of tuberculosis directly from sputum in resource-limited setting seemed to be high.

Keywords: RIF; Xpert; Xpert MTB; in house LAMP; tuberculosis.

PubMed Disclaimer

Conflict of interest statement

No Conflict of Interest is declared

LinkOut - more resources