Is percutaneous pinning an outdated technique for distal radius fractures?
- PMID: 30954251
- DOI: 10.1016/j.injury.2019.03.048
Is percutaneous pinning an outdated technique for distal radius fractures?
Abstract
Distal radius fracture is a very common injury representing 17.5% of all fractures seen in the emergency room. However, the most effective treatment is still unclear and controversially debated. For ten years, we have been facing a true revolution by the increasing use of open reduction and fixation by volar locking plates as an alternative to previous less invasive treatment such as closed reduction and percutaneous k-wire pinning. Several meta-analyses have compared the clinical results after closed reduction and percutaneous pinning and volar locking plate fixation. Volar locking plate fixation achieves better early functional recovery, better radiological outcomes and less minor complications. However, long-term results were similar for both fixation methods. In addition, worse radiological outcomes and more minor complications after closed reduction and percutaneous pinning seem not to be clinically relevant. Interestingly, volar locking plate fixation continues to be a more dominant treatment method compared to percutaneous pinning in operative care of distal radius fractures. Surgeon characteristics such as age, profession as well as location and type of the clinic seem to play a role in the decision for the surgical treatment method. It appears that implant cost plays a minor role in treatment choice between closed reduction and percutaneous pinning and volar locking plate fixation.
Keywords: Distal radius fracture; Kapandji’s technique; Percutaneous pinning; Volar locking plate; Wrist fracture.
Copyright © 2019 Elsevier Ltd. All rights reserved.
Similar articles
-
Are Volar Locking Plates Superior to Percutaneous K-wires for Distal Radius Fractures? A Meta-analysis.Clin Orthop Relat Res. 2015 Sep;473(9):3017-27. doi: 10.1007/s11999-015-4347-1. Epub 2015 May 16. Clin Orthop Relat Res. 2015. PMID: 25981715 Free PMC article. Review.
-
Cost-Effectiveness of Treatments after Closed Extraarticular Distal Radius Fractures in Older Adults from the WRIST Clinical Trial.Plast Reconstr Surg. 2021 Feb 1;147(2):240e-252e. doi: 10.1097/PRS.0000000000007528. Plast Reconstr Surg. 2021. PMID: 33235040 Free PMC article. Clinical Trial.
-
Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures.Injury. 2017 Oct;48 Suppl 3:S24-S29. doi: 10.1016/S0020-1383(17)30653-8. Injury. 2017. PMID: 29025605 Clinical Trial.
-
Volar locking plates versus Kirschner wires for distal radial fractures--a cost analysis study.Injury. 2009 Dec;40(12):1279-81. doi: 10.1016/j.injury.2009.02.018. Epub 2009 Jun 13. Injury. 2009. PMID: 19524910
-
A Comparison Between Volar Locking Plates and Percutaneous Pinning in the Treatment of Distal Radius Fractures: A Systematic Review.J Hand Surg Am. 2025 Mar;50(3):265-273. doi: 10.1016/j.jhsa.2024.08.016. Epub 2024 Oct 8. J Hand Surg Am. 2025. PMID: 39387751
Cited by
-
Experience of Kapandji technique in treating Colles' fracture in central region of Vietnam.SICOT J. 2022;8:41. doi: 10.1051/sicotj/2022040. Epub 2022 Sep 28. SICOT J. 2022. PMID: 36169336 Free PMC article.
-
Trends in Distal Radius Fixation Reimbursement, Charge, and Utilization in the Medicare Population.J Hand Microsurg. 2022 Jun 1;15(4):308-314. doi: 10.1055/s-0042-1748781. eCollection 2023 Sep. J Hand Microsurg. 2022. PMID: 37701309 Free PMC article.
-
Randomized trials evaluating volar locking plates against casting of distal radius fractures are statistically fragile: A systematic review.J Orthop. 2024 Nov 21;64:91-96. doi: 10.1016/j.jor.2024.11.014. eCollection 2025 Jun. J Orthop. 2024. PMID: 39691642 Review.
-
Systematic use of short unicortical epiphyseal locking screws versus full-length unicortical locking screws in distal radius fracture volar plating: A prospective and comparative study.Eur J Orthop Surg Traumatol. 2022 Jan;32(1):11-18. doi: 10.1007/s00590-021-02899-0. Epub 2021 Mar 4. Eur J Orthop Surg Traumatol. 2022. PMID: 33661374
-
Comparison of five percutaneous pinning methods for unstable extra-articular distal radius fractures: A mechanical study using sawbones.Jt Dis Relat Surg. 2021;32(1):51-58. doi: 10.5606/ehc.2021.75817. Epub 2021 Jan 6. Jt Dis Relat Surg. 2021. PMID: 33463418 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical