Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2019 Jun;30(6):836-844.e1.
doi: 10.1016/j.jvir.2018.12.031. Epub 2019 Apr 5.

Balloon-Expandable Vascular Covered Stent in the Treatment of Iliac Artery Occlusive Disease: 9-Month Results from the BOLSTER Multicenter Study

Collaborators, Affiliations
Free article
Clinical Trial

Balloon-Expandable Vascular Covered Stent in the Treatment of Iliac Artery Occlusive Disease: 9-Month Results from the BOLSTER Multicenter Study

John R Laird et al. J Vasc Interv Radiol. 2019 Jun.
Free article

Abstract

Purpose: This study sought to assess the performance of the LIFESTREAM balloon-expandable covered stent for the treatment of iliac artery atherosclerotic lesions.

Methods: A total of 155 patients were treated in a prospective, single-arm study at 17 centers in the United States, Europe, and New Zealand. The primary endpoint was a composite of device- or procedure-related death or myocardial infarction (MI) over the course of 30 days, or target lesion revascularization (TLR), major amputation of the target limb, or re-stenosis through 9-months. Secondary endpoints included primary patency, TLR, sustained clinical success, quality of life, and major adverse events (MAE).

Results: At 9 months, the primary composite endpoint rate was 16.2% (93.5% confidence interval [CI]: 10.6%-23.2%), primary patency was 89.1% (95% CI: 82.6%-93.7%), and freedom from TLR was 96%. There was a cumulative clinical improvement of at least one Rutherford category from baseline to 9 months of 90.5% (95% CI: 84.3%-94.9%). Quality of life, assessed by using the Walking Impairment Questionnaire (WIQ), demonstrated a mean change in total score from baseline through 9 months of 32.1 ± 26.84; overall, improvements were noted from baseline in each WIQ category. Seven of one-hundred fifty patients (4.7%; 95% CI: 1.9%-9.4%) experienced MAEs, but none were determined to be related to device or procedure.

Conclusions: The LIFESTREAM balloon-expandable covered stent provided satisfactory 9-month clinical outcomes including a low rate of target lesion revascularization for the treatment of stenotic and occlusive lesions of the iliac arteries.

PubMed Disclaimer

MeSH terms

LinkOut - more resources