Charged aerosol detector HPLC as a characterization and quantification application of biopharmaceutically relevant polysialic acid from E. coli K1
- PMID: 30961966
- DOI: 10.1016/j.chroma.2019.03.069
Charged aerosol detector HPLC as a characterization and quantification application of biopharmaceutically relevant polysialic acid from E. coli K1
Abstract
Polysialic acid (polySia) is widely investigated in various biopharmaceutical applications (e.g. treatment of inflammatory neurodegenerative diseases), whereby a certain polySia chain length with an average degree of polymerization 20 (polySia avDP20) shows most promising effects. In this study, a rapid analytical method using a HPLC and charged aerosol detector (CAD) for the direct chain length characterization of biopharmaceutically relevant polySia was developed. It was evaluated as a fast alternative to the commonly used 1,2-diamino-4,5-methylenedioxybenzene (DMB) HPLC application. In contrast to HPLC-FLD, the CAD-application provides the actual chain length of polySia within ∼3 h. The reliability of the HPLC-CAD was evaluated with a commercial reference sample of known chain length and biotechnologically produced LC polySia (long chain polySia with a DP ∼130). Moreover, HPLC-CAD was successfully applied in the direct detection of oligo- and polySia until DP ∼65 and can be used to monitor the thermal hydrolysis and subsequent chromatographic isolation of polySia avDP20 (average degree of polymerization 20) without DMB sample derivatization. In addition, CAD was successfully applied for polySia quantification using a modified elution gradient. It was tested as a fast alternative to commonly used thiobarbituric acid (TBA) assay. A differentiation between LC polySia and smaller, hydrolysed polySia chains was intended and possible. For LC polySia and polySia avDP20, a quadratic relation between polySia mass-concentration and CAD signal was observed. In case of LC polySia, a quadratic dependency with a determination coefficient of R2 = 0.99 in a broad concentration range between 0.025 and 15 mg mL-1 was determined. Quantification of polySia avDP20 was found to have quadratic dependency with a determination coefficient of R2 = 0.99 in a concentration range between 0.02 and 0.25 mg mL-1. The HPLC-CAD was tested for quantification with polySia references of known concentration and showed high accordance with a concentration deviation ≤6.7%. The CAD quantification method was also applied in the polySia avDP20 production process and was compared to the TBA assay. Results of a correlation plot showed a high determination coefficient of R2 = 0.98. Overall, HPLC-CAD analysis was successfully tested as a suitable characterization and quantification application in the biopharmaceutical production of polySia.
Keywords: Calibration; Chain length distribution; Charged aerosol detector (CAD); Polymer analysis; Polysialic acid (polySia); Quantification.
Copyright © 2019 Elsevier B.V. All rights reserved.
Similar articles
-
Determination of the Structural Integrity and Stability of Polysialic Acid during Alkaline and Thermal Treatment.Molecules. 2019 Dec 31;25(1):165. doi: 10.3390/molecules25010165. Molecules. 2019. PMID: 31906121 Free PMC article.
-
Improved methods to characterize the length and quantity of highly unstable PolySialic acids subject category: (Carbohydrates, chromatographic techniques).Anal Biochem. 2021 Dec 15;635:114426. doi: 10.1016/j.ab.2021.114426. Epub 2021 Oct 20. Anal Biochem. 2021. PMID: 34687617 Free PMC article.
-
Low molecular weight polysialic acid prevents lipopolysaccharide-induced inflammatory dopaminergic neurodegeneration in humanized SIGLEC11 transgenic mice.Glia. 2021 Dec;69(12):2845-2862. doi: 10.1002/glia.24073. Epub 2021 Aug 18. Glia. 2021. PMID: 34406679
-
Charged aerosol detection in pharmaceutical analysis.J Pharm Biomed Anal. 2012 Oct;69:50-63. doi: 10.1016/j.jpba.2012.03.019. Epub 2012 Mar 21. J Pharm Biomed Anal. 2012. PMID: 22487591 Review.
-
Forced degradation and impurity profiling: recent trends in analytical perspectives.J Pharm Biomed Anal. 2013 Dec;86:11-35. doi: 10.1016/j.jpba.2013.07.013. Epub 2013 Jul 31. J Pharm Biomed Anal. 2013. PMID: 23969330 Review.
Cited by
-
Low molecular weight polysialic acid binds to properdin and reduces the activity of the alternative complement pathway.Sci Rep. 2022 Apr 6;12(1):5818. doi: 10.1038/s41598-022-09407-2. Sci Rep. 2022. PMID: 35388026 Free PMC article.
-
Polysialic Acid in the Immune System.Front Immunol. 2022 Feb 11;12:823637. doi: 10.3389/fimmu.2021.823637. eCollection 2021. Front Immunol. 2022. PMID: 35222358 Free PMC article. Review.
-
Determination of the Structural Integrity and Stability of Polysialic Acid during Alkaline and Thermal Treatment.Molecules. 2019 Dec 31;25(1):165. doi: 10.3390/molecules25010165. Molecules. 2019. PMID: 31906121 Free PMC article.
-
Accelerated production of α2,8- and α2,9-linked polysialic acid in recombinant Escherichia coli using high cell density cultivation.Biotechnol Rep (Amst). 2020 Nov 18;28:e00562. doi: 10.1016/j.btre.2020.e00562. eCollection 2020 Dec. Biotechnol Rep (Amst). 2020. PMID: 33304838 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous