. 2019 Dec;23(12):4425-4431.
doi: 10.1007/s00784-019-02885-1. Epub 2019 Apr 13.

Accuracy of orthodontic mini-implants placed at the anterior palate by tooth-borne or gingiva-borne guide support: a cadaveric study

Affiliations

Accuracy of orthodontic mini-implants placed at the anterior palate by tooth-borne or gingiva-borne guide support: a cadaveric study

Stephan Christian Möhlhenrich et al. Clin Oral Investig. 2019 Dec.

Abstract

Objective: The aim of this cadaveric study was to measure the transfer accuracy of orthodontic mini-implant placement at the anterior palate depending on tooth-borne or gingiva-borne guide support.

Materials and methods: Forty orthodontic mini-implants were placed paramedian in the anterior palate of 20 cadaver heads using tooth-borne (TBG) or gingiva-borne guides (GBG). Placement was planned after superimposition of lateral cephalograms and corresponding plaster models. After mini-implant placement, digital impressions were taken with scanbodies. For the measurement of both linear and angle deviations, virtual planning models and postoperative oral scans were compared using automatic surface registration based on an iterative closest point algorithm.

Results: Statistical differences between TBG and GBG were detected for lateral deviations 0.88 mm (SD 0.46) versus 1.65 mm (SD 1.03) (p = .004) and sagittal angular deviations 3.67° (SD 2.25) versus 6.46° (SD 5.5) (p = .043). No differences were found for vertical deviations 2.34 mm (SD 0.74) versus 2.14 mm (SD 0.73) (p = .40) and transverse angular deviations 3.60° (SD 2.89) versus 4.06° (SD 3.04) (p = .62).

Conclusions: The use of surgical guides based on silicone provides sufficient control of orthodontic mini-implant placement and is comparable to CAD/CAM templates. However, when compared with guided dental implantology, the planned mini-implant position is more inaccurate. However, accuracy can be significantly increased by guide extension involving the teeth. Clinical investigations have to prove if the accuracy is sufficient for receiving an orthodontic appliance.

Clinical relevance: The use of lateral cephalograms and plaster models for silicone guide construction leads to lower radiation exposure and provides sufficient accuracy for palatal orthodontic mini-implant placement.

Keywords: Mini-implant; Orthodontic implants; Orthodontics; Surgical guides; Surgical templates; Temporary anchorage device (TAD); Transfer accuracy.

PubMed Disclaimer

References

    1. J Orofac Orthop. 1996 Jun;57(3):142-53 - PubMed
    1. Clin Oral Implants Res. 2013 Jul;24(7):763-9 - PubMed
    1. Int J Oral Maxillofac Surg. 2018 Sep;47(9):1195-1198 - PubMed
    1. Clin Oral Implants Res. 2014 Sep;25(9):1091-3 - PubMed
    1. Kaohsiung J Med Sci. 2015 May;31(5):265-70 - PubMed

Substances

LinkOut - more resources