Twenty-four-month clinical performance of different universal adhesives in etch-and-rinse, selective etching and self-etch application modes in NCCL - a randomized controlled clinical trial
- PMID: 30994773
- PMCID: PMC6459227
- DOI: 10.1590/1678-7757-2018-0358
Twenty-four-month clinical performance of different universal adhesives in etch-and-rinse, selective etching and self-etch application modes in NCCL - a randomized controlled clinical trial
Abstract
Objective: The aim of this randomized, controlled, prospective clinical trial was to evaluate the performances of two different universal adhesives and one etch-rinse adhesive for restoration of non-carious cervical lesions (NCCLs).
Material and methods: Twenty patients with at least seven NCCLs were enrolled. Lesions were divided into seven groups according to adhesive systems and application modes: GSE: GLUMA Universal-self-etch, GSL: GLUMA Universal-selective etching, GER: GLUMA Universal-etch-and-rinse, ASE: All-Bond Universal-self-etch, ASL: All-Bond Universal-selective etching, AER: All-Bond Universal-etch-and-rinse, SBE (Control): Single Bond2-etch-and-rinse. A total of 155 NCCLs were restored with a nano hybrid composite (Tetric N-Ceram). Restorations were scored with regard to retention, marginal discoloration, marginal adaptation, recurrent caries and post-operative sensitivity using modified United States Public Health Service (USPHS) criteria after one week, 6, 12 and 24 months. Statistical evaluations were performed using Chi-square tests (p=0.05).
Results: The recall rate was 81.9% after the 24-month follow-up. The cumulative retention rates for self-etch groups (GSE: 72.2%, ASE:75%) were significantly lower than other experimental groups (GSL: 93.7%, GER: 100%, ASL: 94.1%, AER: 100%, SBE: 100%) at the 24-month follow-up (p<0.05). Regarding marginal adaptation and marginal discoloration, GSE and ASE groups demonstrated more bravo scores after 6 and 12-month observations but differences were not significant (p>0.05). Only one restoration from ASL group demonstrated post-operative sensitivity at 6 and 12-month observations. No secondary caries was observed on the restorations at any recall. At the end of 24-month observations, no significant differences were detected among groups regarding any of the criteria assessed, except retention.
Conclusion: GLUMA Universal and All-Bond Universal showed better results in etch-and-rinse and selective etching mode compared to the self-etch mode regarding retention. Etch-and-rinse and selective etching application modes of the current universal adhesives tended to provide better clinical outcomes considering the criteria evaluated at the end of 24-month evaluation.
Conflict of interest statement
Conflict of Interest
The authors declare no conflicts of interest.
Figures
References
-
- Borcic J, Anic I, Urek MM, Ferreri S. The prevalence of non-carious cervical lesions in permanent dentition. J Oral Rehabil. 2004;31(2):117–123. - PubMed
-
- Levitch LC, Bader JD, Shugars DA, Heymann HO. Non-carious cervical lesions. J Dent. 1994;22(4):195–207. - PubMed
-
- Porto IC, Andrade AK, Montes MA. Diagnosis and treatment of dentinal hypersensitivity. J Oral Sci. 2009;51(3):323–332. - PubMed
-
- Van Dijken JW. Durability of three simplified adhesive systems in Class V non-carious cervical dentin lesions. Am J Dent. 2004;17(1):27–32. - PubMed
-
- Boushell LW, Heymann HO, Ritter AV, Sturdevant JR, Swift EJ, Jr, Wilder AD, Jr, et al. Six-year clinical performance of etch-and-rinse and self-etch adhesives. Dent Mater. 2016;32(9):1065–1072. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical