Does surgeon experience influence the amount of radiation exposure during orthopedic procedures? A systematic review
- PMID: 30996838
- PMCID: PMC6452094
- DOI: 10.4081/or.2019.7667
Does surgeon experience influence the amount of radiation exposure during orthopedic procedures? A systematic review
Abstract
With an increasing use of intraoperative fluoroscopy in operating rooms worldwide, the topic of radiation exposure has become a major concern among hospital staff, doctors and patients alike. Since fluoroscopy has become an integral part in orthopedic intraoperative management, we sought to identify whether surgeon grade or experience plays a role in the amount of radiation used and consequently exposed. We performed a systematic review examining the association between surgeon experience and radiation exposure using primary outcome measures (radiation dose and total screening time/fluoroscopy time). To be included in the review, the study population had to compare varying surgeon experience levels and their effect on the primary outcomes. A total of eighteen studies were included in the review. The studies were a mix of prospective and retrospective studies with low to moderate quality as evaluated by the MINORs criteria. Studies were variable in defining surgeon experience levels and in the type of operations being performed. Majority of the studies showed that inexperienced surgeons/trainees had a higher total fluoroscopy time and a higher mean radiation exposure as compared to experienced surgeons. We conclude that higher surgeon experience significantly reduces usage of fluoroscopy and the consequent radiation exposure in orthopedic procedures. Introduction of strict radiation guidelines involving limited usage of fluoroscopy and supervision of trainees may be beneficial in controlling radiation exposure in the future.
Keywords: Fluoroscopy; Radiation; Radiation Exposure; Surgeon experience.
Conflict of interest statement
Conflict of interest: the authors declare no potential conflict of interest.
Figures
Similar articles
-
Can We Improve Workflows in the OR? A Comparison of Quality Perceptions and Preoperative Efficiency across Institutions in Spine Surgery.Bull Hosp Jt Dis (2013). 2015 Mar;73(1):46-53. Bull Hosp Jt Dis (2013). 2015. PMID: 26517001
-
Evaluation of surgeon and patient radiation exposure by imaging technology in patients undergoing thoracolumbar fusion: systematic review of the literature.Spine J. 2019 Aug;19(8):1397-1411. doi: 10.1016/j.spinee.2019.04.003. Epub 2019 Apr 9. Spine J. 2019. PMID: 30974238
-
Radiation exposure from fluoroscopy during orthopedic surgical procedures.Clin Orthop Relat Res. 1989 Nov;(248):257-60. Clin Orthop Relat Res. 1989. PMID: 2805490
-
Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience.Indian J Orthop. 2008 Oct;42(4):471-3. doi: 10.4103/0019-5413.43398. Indian J Orthop. 2008. PMID: 19753238 Free PMC article.
-
C-arm fluoroscopy in orthopaedic surgical practice.Eur J Orthop Surg Traumatol. 2018 Dec;28(8):1563-1568. doi: 10.1007/s00590-018-2234-7. Epub 2018 May 23. Eur J Orthop Surg Traumatol. 2018. PMID: 29796825 Review.
Cited by
-
Accuracy of robot-assisted versus conventional freehand pedicle screw placement in spine surgery: a systematic review and meta-analysis of randomized controlled trials.Ann Transl Med. 2020 Jul;8(13):824. doi: 10.21037/atm-20-1106. Ann Transl Med. 2020. PMID: 32793669 Free PMC article. Review.
-
K-wire Made Easy by Premarking Wire Trajectory on the Skin in Management of Finger Fractures.Plast Reconstr Surg Glob Open. 2021 Sep 17;9(9):e3797. doi: 10.1097/GOX.0000000000003797. eCollection 2021 Sep. Plast Reconstr Surg Glob Open. 2021. PMID: 34548997 Free PMC article.
-
[Detection of ionizing radiation in operating room and hospital areas].Rev Med Inst Mex Seguro Soc. 2024 Jul 1;62(4):1-6. doi: 10.5281/zenodo.11396957. Rev Med Inst Mex Seguro Soc. 2024. PMID: 39541221 Free PMC article. Spanish.
-
Intraoperative fluoroscopy skills in distal radius fracture surgery: valid and reliable assessment on a novel immersive virtual reality simulator.Acta Orthop. 2024 Aug 28;95:477-484. doi: 10.2340/17453674.2024.41345. Acta Orthop. 2024. PMID: 39192817 Free PMC article.
-
THE USE OF ADHESIVE RADIOPAQUE GRIDS IN GENICULAR NERVE BLOCK BY RADIOSCOPY.Acta Ortop Bras. 2023 Jul 17;31(3):e266060. doi: 10.1590/1413-785220233103e266060. eCollection 2023. Acta Ortop Bras. 2023. PMID: 37469498 Free PMC article.
References
-
- Riley SA. Radiation exposure from fluoroscopy during orthopedic surgical procedures. Clin orthop relat res 1989:257-60. - PubMed
-
- Singer G. Occupational radiation exposure to the surgeon. J Am Acad Orthop Surg 2005;13:69-76. - PubMed
-
- Radhi AM, Masbah O, Shukur MH, et al. Radiation exposure to operating theatre personnel during fluoroscopic-assisted orthopaedic surgery. Med J Malaysia 2006;61:50-2. - PubMed