Leg electrical resistance predicts venous blood viscosity and hematocrit
- PMID: 31006677
- DOI: 10.3233/CH-199003
Leg electrical resistance predicts venous blood viscosity and hematocrit
Abstract
We previously reported that whole body bioelectrical impedance analysis (BIA) measurements are correlated to some hemorheologic factors, suggesting a relationship between viscosity factors and electric properties of flowing blood not only in vitro but also in vivo. Recently we reported that with segmental BIA (analyzing the body considered as composed of 5 cylinders) predictive equations for various determinants of blood viscosity were closer than for the wole body. Another widely used BIA technique uses leg-to-leg impedance measurements so that two cylinders (the two legs) are analyzed. We investigated whether impedance measured with this technique (Tanita TBF-300) is also a predictor of blood viscosity factors. From viscometric measurements performed on venous blood drawn in recreative athletes over the range of shear rates 1 to 6000 s-1 (RHEOMETRE Anton Paar CP 50-1), we found a correlation between leg-leg resistance at 50 kHz (Rx[50 kHz]) and blood viscosity at 1000 s-1 (η1000= 0.0051 Rx[50 kHz] + 1.3265; r = 0.521 p = 0.028 yielding a prediction of η1000 (Bland Altman plot: bias 0.05 [RANGE - 0.24; 0.34]. Neither plasma viscosity nor the red cell rheology index «k» of Quemada's model are correlated with Rx[50 kHz], but hematocrit (Hct) does (Hct (%) = 0.0217 Rx[50 kHz] + 33.783; r = 0.480 p = 0.044) yielding a prediction of Hct (Bland Altman plot: bias - 0.11, [range - 1.67; 1.45]. The discrepancy between actual and predicted Hct is also correlated with resistance at 50 kHz (r = 0.575 p = 0.031) as does the discrepancy between actual and predicted Hct/viscosity ratio (r = -0.651 p = 0.006). Therefore, as other previously studied methods, leg to leg BIA predicts viscosity, suggesting that blood rheology may influence the passage of an electric current in the legs.
Keywords: Myrenne aggregometer; Red blood cell aggregation; Segmental bioelectrical impedance; electrical conductance; hematocrit; light transmission.
Similar articles
-
Segmental bioelectrical impedance analysis (SBIA) and blood rheology: Reducing the gap between in vivo and in vitro?Clin Hemorheol Microcirc. 2016;64(4):603-611. doi: 10.3233/CH-168041. Clin Hemorheol Microcirc. 2016. PMID: 27792002
-
Prediction of RBC aggregability and deformability by whole body bioimpedance measurements analyzed according to Hanai's mixture conductivity theory.Clin Hemorheol Microcirc. 2011;47(2):151-61. doi: 10.3233/CH-2010-1378. Clin Hemorheol Microcirc. 2011. PMID: 21339635
-
Shear-dependency of the predicted ideal hematocrit.Clin Hemorheol Microcirc. 2019;71(4):379-385. doi: 10.3233/CH-199001. Clin Hemorheol Microcirc. 2019. PMID: 31006675
-
Exercise hemorheology: Moving from old simplistic paradigms to a more complex picture.Clin Hemorheol Microcirc. 2013;55(1):15-27. doi: 10.3233/CH-131686. Clin Hemorheol Microcirc. 2013. PMID: 23478223 Review.
-
New trends in clinical hemorheology: an introduction to the concept of the hemorheological profile.Schweiz Med Wochenschr Suppl. 1991;43:41-9. Schweiz Med Wochenschr Suppl. 1991. PMID: 1843037 Review.
Cited by
-
Longitudinal Effect of Hemoglobin Concentration With Incident Ischemic Heart Disease According to Hepatic Steatosis Status Among Koreans.Front Cardiovasc Med. 2021 May 28;8:677040. doi: 10.3389/fcvm.2021.677040. eCollection 2021. Front Cardiovasc Med. 2021. PMID: 34124205 Free PMC article.
-
Phase angle and water cell distribution as inflammation indicators linked to hematological markers across BMI categories.Sci Rep. 2025 May 9;15(1):16147. doi: 10.1038/s41598-025-98430-0. Sci Rep. 2025. PMID: 40341652 Free PMC article.
-
Phase angle and extracellular water-to-total body water ratio estimated by bioelectrical impedance analysis are associated with levels of hemoglobin and hematocrit in patients with diabetes.Heliyon. 2023 Mar 21;9(4):e14724. doi: 10.1016/j.heliyon.2023.e14724. eCollection 2023 Apr. Heliyon. 2023. PMID: 37057050 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous