. 2019 Aug;213(2):404-409.
doi: 10.2214/AJR.18.20950. Epub 2019 Apr 23.

Iodine Dose of Administered Contrast Media Affects the Level of Radiation-Induced DNA Damage During Cardiac CT Scans

Affiliations

Iodine Dose of Administered Contrast Media Affects the Level of Radiation-Induced DNA Damage During Cardiac CT Scans

Toon Van Cauteren et al. AJR Am J Roentgenol. 2019 Aug.

Abstract

OBJECTIVE. The purpose of this study is to investigate the contributing effect of contrast media (CM) iodine dose on radiation-induced DNA damage in blood lymphocytes during a cardiac CT scan. MATERIALS AND METHODS. The minipigs were exposed 12 times in total to a fixed cardiac CT scan protocol. An unenhanced and two CM injection protocols were considered, the latter with 50% saline diluted (160 mg I/mL) and standard iodixanol. Blood samples were collected before and after CT, and radiation-induced DNA double-strand breaks were assessed using γ-H2AX (H2A histone family member X) immunofluorescent staining of the blood lymphocytes. Significant differences in foci numbers were investigated with an independent sample t test. In addition, a numeric dosimetry model was applied that simulates the cardiac CT scan, with the heart represented by a blood volume containing a mixture of six iodine concentrations (0, 10, 20, 30, 40, and 50 mg I/mL). RESULTS. Compared with the unenhanced (0 mg I/mL) protocol, the number of γ-H2AX foci per cell increased significantly (p < 0.038), by 56.1% for the reduced iodine dose (160 mg I/mL) and by 141.1% for the standard iodine dose (320 mg I/mL) protocols. These in vivo results are confirmed by the dosimetry simulation model, in which 78.8% and 133.7% increases in locally absorbed blood dose in the left ventricle were observed for the reduced and standard iodine dose protocols, respectively. CONCLUSION. Administration of CM during a cardiac CT examination significantly increases radiation-induced DNA damage in blood lymphocytes. Moreover, a lower CM iodine dose results in a reduced level of DNA damage, at constant radiation exposure.

Keywords: cardiac CT; iodinated contrast media; minipigs; patient safety; radiation-induced DNA damage.