Fresh gas flow in coaxial Mapleson A and D circuits during spontaneous breathing
- PMID: 3101384
- DOI: 10.1111/j.1399-6576.1986.tb02481.x
Fresh gas flow in coaxial Mapleson A and D circuits during spontaneous breathing
Abstract
In a lung model simulating spontaneously breathing halothane anaesthesia, the rebreathing characteristics of the coaxial Mapleson A (Lack circuit) and D (Bain circuit) systems were tested. Using decreasing fresh gas flows (VF), the end-tidal carbon dioxide fraction (FACO2) was monitored and the point of rebreathing (R.P.) detected. The effects of changes in minute volume (VE), dead-space to tidal volume ratio (VD/VT) and carbon dioxide elimination (VCO2) were studied. The effect of increased tidal volumes (VT) on FACO2 was investigated for some different fresh gas flows (VF). The VF/VE ratio for R.P. in the Bain circuit was approximately 2 and in the Lack circuit 0.88. In both circuits an increase in VE and a decrease in the VD/VT ratio resulted in higher demands on VF if rebreathing was to be avoided. The latter effect was much more pronounced in the Lack circuit. In neither system did any changes in VCO2 affect the rebreathing characteristics. The conclusion was drawn that the Lack system is a much better choice concerning the fresh gas flows for anaesthesia with spontaneous breathing than the Bain system. It was also concluded that the fresh gas flows recommended by Humphrey for the Lack system (i.e. 51 ml X min-1 X kg b.w.-1) and by the manufacturers for the Bain system (i.e. 100 ml X min-1 X kg b.w.-1) are inadequate and should be increased if a considerable degree of rebreathing is to be avoided.
Similar articles
-
Mapleson's Breathing Systems.Indian J Anaesth. 2013 Sep;57(5):507-15. doi: 10.4103/0019-5049.120148. Indian J Anaesth. 2013. PMID: 24249884 Free PMC article. Review.
-
Calculation of end-tidal carbon dioxide fractions in the Bain system.Acta Anaesthesiol Scand. 1989 Jan;33(1):71-4. doi: 10.1111/j.1399-6576.1989.tb02863.x. Acta Anaesthesiol Scand. 1989. PMID: 2492710
-
A new hybrid anaesthetic circuit for a low-flow rebreathing technique.Acta Anaesthesiol Scand. 1994 Nov;38(8):840-4. doi: 10.1111/j.1399-6576.1994.tb04015.x. Acta Anaesthesiol Scand. 1994. PMID: 7887108
-
Physical characteristics of an enclosed afferent reservoir breathing system.Br J Anaesth. 1992 Jun;68(6):625-9. doi: 10.1093/bja/68.6.625. Br J Anaesth. 1992. PMID: 1344024
-
[Function of anesthesia systems with different flow rates of fresh gas].Ann Fr Anesth Reanim. 1987;6(5):378-80. doi: 10.1016/s0750-7658(87)80358-1. Ann Fr Anesth Reanim. 1987. PMID: 3324833 Review. French. No abstract available.
Cited by
-
Mapleson's Breathing Systems.Indian J Anaesth. 2013 Sep;57(5):507-15. doi: 10.4103/0019-5049.120148. Indian J Anaesth. 2013. PMID: 24249884 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous