Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2019 Aug 1:288:82-86.
doi: 10.1016/j.ijcard.2019.04.020. Epub 2019 Apr 8.

Same-day CIED implantation and discharge: Is it possible? The E-MOTION trial (Early MObilization after pacemaker implantaTION)

Affiliations
Free article
Randomized Controlled Trial

Same-day CIED implantation and discharge: Is it possible? The E-MOTION trial (Early MObilization after pacemaker implantaTION)

Carlo Budano et al. Int J Cardiol. .
Free article

Abstract

Background: Despite the increasing number of cardiac implantable electronic devices (CIED) procedures worldwide, no guideline assessed postoperative mobilization protocols. Lacking evidences in literature, many centers require 24-hour immobilization and bed rest to minimize the risk of pacing lead (PL) dislodgement. Prolonged immobilization may futilely delay discharge, induce pain and reduced joint mobility especially in elderly patients. We examined whether early mobilization at 3-h after CIED surgery would result in higher complication rates, compared with standard 24-hour immobilization.

Methods: Consecutive patients undergoing CIED implantation were randomized to early (3-h) mobilization protocol with an arm sling support (E-motion group, EMG) vs. standard (24-h) immobilization (control group, CG). The primary end-point was 24-month PL dislodgement. Secondary safety end-point was any major intra-procedural complication (cardiac perforation, pericardial tamponade, valve damage, haemothorax, pneumothorax, myocardial infarction, peripheral embolus, TIA/stroke or death).

Results: Among 200 enrolled patients, 86% underwent pacemaker implantation (28% single-chamber, 72% dual-chamber device), 14% underwent ICD implantation (75% single-chamber, 25% dual-chamber device). PL fixation was mostly passive (97% atrial PL, 88% ventricular PL), without differences between EMG and CG (p = 0.99). No differences were observed in the incidence of 24-month PL dislodgement (3% in the EMG vs. 4% in the CG, p = 0.99). No major intra-procedural complications were observed.

Conclusions: Early mobilization at 3-h following CIED surgery is safe and feasible compared with standard immobilization and is not associated with an increased risk of intra-procedural complications or 24-month lead dislodgment. So, same-day implantation and discharge might be possible.

Keywords: Cardiac implantable electronic device; Implantable-cardioverter-defibrillator; Pacemaker.

PubMed Disclaimer

Publication types