. 2019 May;33(5):1208-1215.
doi: 10.1519/JSC.0000000000003113.

Reliability and Validity of a Pool-Based Maximal Oxygen Uptake Test to Examine High-Intensity Short-Duration Freestyle Swimming Performance

Affiliations

Reliability and Validity of a Pool-Based Maximal Oxygen Uptake Test to Examine High-Intensity Short-Duration Freestyle Swimming Performance

Elizabeth F Nagle et al. J Strength Cond Res. 2019 May.

Abstract

Nagle, EF, Nagai, T, Beethe, AZ, Lovalekar, MT, Zera, JN, Connaboy, C, Abt, JP, Beals, K, Nindl, BC, Robertson, RJ, and Lephart, SM. Reliability and validity of a pool-based maximal oxygen uptake test to examine high-intensity short-duration freestyle swimming performance. J Strength Cond Res 33(5): 1208-1215, 2019-A modality-specific swimming protocol to assess maximal oxygen uptake (V[Combining Dot Above]O2maxsw) is essential to accurately prescribe and monitor swimming conditioning programs. Consequently, there is a need for a reliable and valid graded intensity swimming pool test to accurately assess V[Combining Dot Above]O2maxsw using indirect calorimetry. The purpose of this study was to assess (a) reliability of an intensity self-regulated swimming pool test of V[Combining Dot Above]O2maxsw and (b) validity of a V[Combining Dot Above]O2maxsw test using performance swim (PS) time as the criterion. Twenty-nine men (n = 15) and women (n = 14) (age, 23 ± 6.4 years; body mass index, 23.5 ± 3.0 kg·m) performed 2 swimming pool V[Combining Dot Above]O2maxsw trials (V[Combining Dot Above]O2maxsw A and V[Combining Dot Above]O2maxsw B), and 2 PS tests (45.7 m [31.20 ± 4.5 seconds] and 182 m [159.2 ± 25.5 seconds]). For test-retest reliability (trials A vs. B), strong correlations (p < 0.05) were found for V[Combining Dot Above]O2maxsw (ml·kg·min) (r = 0.899), O2 pulse (ml O2·beat) (r = 0.833), and maximum expired ventilatory volume (L·min) (r = 0.785). For performance validity, moderately strong correlations (p < 0.05) were found between V[Combining Dot Above]O2maxsw A and 45.7-m (r = -0.543) and 182-m (r = -0.486) swim times. The self-regulated graded intensity swimming pool protocol examined presently is a reliable and valid test of V[Combining Dot Above]O2maxsw. Studies should consider the suitability of a V[Combining Dot Above]O2maxsw test for military personnel, clinical populations, and injured athletes.