. 2019 Jun;33(3):478-481.
doi: 10.1007/s00540-019-02650-4. Epub 2019 May 6.

Near-infrared spectroscopy underestimates cerebral oxygenation in hemodialysis patients

Affiliations
Free article

Near-infrared spectroscopy underestimates cerebral oxygenation in hemodialysis patients

Shino Matsukawa et al. J Anesth. 2019 Jun.
Free article

Abstract

Regional cerebral oxygen saturation (rSO2) measured using near-infrared spectroscopy has been reported to be significantly lower in hemodialysis (HD) patients than in non-HD ones, but the mechanisms are unknown. The aim of this prospective study was to assess the accuracy of near-infrared spectroscopy to estimate cerebral oxygenation in HD patients undergoing cardiovascular surgery. Our hypothesis was that rSO2 values would underestimate cerebral oxygenation in HD patients. This study included 113 patients (7 HD patients and 106 non-HD ones) undergoing cardiac or major aortic surgery between December 2015 and November 2017. We evaluated the validity of rSO2 by comparing it with ipsilateral jugular venous oxygen saturation (SjvO2). In HD and non-HD patients, rSO2 and SjvO2 showed a weak correlation (R2: 0.46 and 0.28 in HD and non-HD patients, respectively). Bland-Altman analysis revealed that bias (95% limits of agreement) of rSO2 compared to SjvO2 was - 19.2% ( - 41.7-3.3%) in HD patients and - 1.9% (- 19.3-15.5%) in non-HD ones. The large negative bias suggests that the rSO2 values measured using near-infrared spectroscopy substantially underestimate cerebral oxygenation in HD patients.

Keywords: Hemodialysis; Jugular venous oxygen saturation; Near-infrared spectroscopy; Regional cerebral oxygen saturation.

PubMed Disclaimer

Comment in

  • Response to letter to the editor.
    Matsukawa S, Kai S, Mizota T. Matsukawa S, et al. J Anesth. 2020 Feb;34(1):157. doi: 10.1007/s00540-019-02665-x. Epub 2019 Jul 19. J Anesth. 2020. PMID: 31324983 No abstract available.
  • Cerebral oxygenation in hemodialysed patients.
    Tan YW, Lean LL, Paramasivan A. Tan YW, et al. J Anesth. 2020 Feb;34(1):156. doi: 10.1007/s00540-019-02664-y. Epub 2019 Jul 23. J Anesth. 2020. PMID: 31338580 No abstract available.

References

    1. Am J Nephrol. 2000 Jan-Feb;20(1):27-31 - PubMed
    1. Anesth Analg. 2000 Mar;90(3):559-66 - PubMed
    1. J Clin Monit Comput. 2000;16(3):191-9 - PubMed
    1. Anesthesiology. 2007 Mar;106(3):458-62 - PubMed
    1. J Cereb Blood Flow Metab. 2007 Nov;27(11):1861-9 - PubMed

Publication types