Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2019 Mar 31;10(1):e5.
doi: 10.5037/jomr.2019.10105. eCollection 2019 Jan-Mar.

Restoring Edentulous Mandible with an Implant-Retained Overdenture in a Day by Means of Flapless Surgery and Stereolithographic Surgical Guide: a Case Report

Affiliations
Case Reports

Restoring Edentulous Mandible with an Implant-Retained Overdenture in a Day by Means of Flapless Surgery and Stereolithographic Surgical Guide: a Case Report

Ilser Turkyilmaz. J Oral Maxillofac Res. .

Abstract

Background: Digital revolution is here and becoming more and more influential in our daily lives by transforming several things such as our habits, interactions with other people and the practice of dentistry. In implant dentistry, the newer methods by using cone-beam computed tomography and computer-aided design and computer-aided manufacturing recently offer more predictable and aesthetics outcomes in a shorter period of treatment time when compared to the traditional prosthetic procedures.

Methods: A 66 year-old male patient with an edentulous mandible and several failing maxillary teeth presented to our clinic. After cone-beam computed-tomography scans and virtual implant placement by using three-dimensional software, a stereolithographic surgical guide was fabricated. The patient received two mandibular implants without any flap elevation by means of a computer-aided design and computer-aided manufacturing surgical guide and a maxillary complete denture in a day.

Results: The surgical and restorative procedures were performed without any issues. The patient was followed-up for three years and no major complications with the implants and prostheses were observed.

Conclusions: The technique illustrated in this report may be successfully used to restore edentulous arches in a day if it is executed by trained restorative dentists and if patient selection is appropriate.

Keywords: CAD/CAM; cone-beam CT; implant; overdenture; stereolithography; surgery.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Presurgical panoramic radiograph of the patient.
Figure 2
Figure 2
A = occlusal view of the completed virtual implant placement and computer-aided design and computer-aided manufacturing (CAD/CAM) surgical guide. B = CAD/CAM surgical guide after fabrication. C = flapless implant placement through the metal sleeves of the CAD/CAM surgical guide. D = intraoral view of two mandibular implants immediately after implant placement.
Figure 3
Figure 3
A = internal view of the implant-retained mandibular overdenture. B = intraoral view of the patient after both duplicate trial dentures were inserted. C = intraoral view of the patient with new denture teeth were arranged. D = intraoral view of the patient after both maxillary complete denture and implant-retained mandibular overdenture were delivered.

References

    1. Van Assche N, Fickl S, Francisco H, Gurzawska K, Milinkovic I, Navarro JM, Torsello F, Thoma DS. Guidelines for development of Implant Dentistry in the next 10 years regarding innovation, education, certification, and associations. Clin Oral Implants Res. 2018 Jun;29(6):568-575. - DOI - PubMed
    1. Turkyilmaz I, Asar NV. Eighteen-Month Outcomes of Titanium Frameworks Using Computer-Aided Design and Computer-Aided Manufacturing Method. Implant Dent. 2017 Jun;26(3):480-484. - DOI - PubMed
    1. Dano D, Stiteler M, Giordano R. Prosthetically Driven Computer-Guided Implant Placement and Restoration Using CEREC: A Case Report. Compend Contin Educ Dent. 2018 May;39(5):311-317. - PubMed
    1. Jorba-García A, Figueiredo R, González-Barnadas A, Camps-Font O, Valmaseda-Castellón E. Accuracy and the role of experience in dynamic computer guided dental implant surgery: An in-vitro study. Med Oral Patol Oral Cir Bucal. 2019 Jan 1;24(1):e76-e83. - DOI - PMC - PubMed
    1. Turbush SK, Turkyilmaz I. Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study. J Prosthet Dent. 2012 Sep;108(3):181-8. - DOI - PubMed

Publication types

LinkOut - more resources