Is Digital Guided Implant Surgery Accurate and Reliable?
- PMID: 31097133
- DOI: 10.1016/j.cden.2019.02.006
Is Digital Guided Implant Surgery Accurate and Reliable?
Abstract
The digital workflow for computer-aided implant surgery includes a range of steps leading to generation of a prosthetically driven, 3-dimensional virtual plan, which is transitioned into the patient's mouth by the surgical guide and protocol. Guided implant surgery is believed to be accurate and reliable compared with free-handed implant surgery. However, deviation between implant virtual plan and implant real position may occur as a result of accumulated errors throughout the digital workflow. This article reviews the digital workflow of static computer-aided implant surgery. Factors that may affect the accuracy and clinical outcome of the guided surgery are also reviewed.
Keywords: Accuracy; Computer-aided surgery; Computer-assisted surgery; Dental implants; Digital workflow; Implant-guided surgery; Virtual plan.
Copyright © 2019 Elsevier Inc. All rights reserved.