Cervical modifications after pessary placement in singleton pregnancies with maternal short cervical length: 2D and 3D ultrasound evaluation
- PMID: 31102541
- DOI: 10.1111/aogs.13647
Cervical modifications after pessary placement in singleton pregnancies with maternal short cervical length: 2D and 3D ultrasound evaluation
Abstract
Introduction: The use of a pessary proved to prevent preterm birth in asymptomatic women with mid-trimester short cervical length (CL); however, the precise mechanisms by which the pessary confers its benefit remain unclear. The aim of this study was to evaluate multiple cervical characteristics assessed by 2-dimensional and 3-dimensional ultrasound before and after placement of a cervical pessary to ascertain its mechanism of action.
Material and methods: In this prospective cohort study, we assessed the cervical characteristics in singleton pregnancies with maternal short CL and compared them with matched reference women with normal CL. The variables evaluated were: CL, uterocervical angles, cervical consistency indices (cervical consistency index and CL consistency index), cervical volume and vascular indices. All variables were re-assessed immediately after pessary placement and 4-6 weeks later in all participants. Mann-Whitney U test was used to assess differences between groups and paired samples t test for comparisons in two different examinations in the same women. The aim of this study was to evaluate multiple cervical ultrasound variables before and after the placement of a cervical pessary and compare the evolution of these variables with a reference group with normal CL to better understand the device's mechanism of action.
Results: Thirty-three women with short CL and 24 reference women with normal CL were enrolled. At the time of enrollment, gestational age and maternal baseline characteristics did not differ between groups. Immediately after pessary placement, CL increased, uterocervical angles were narrower and cervical consistency increased significantly. When the magnitude of change in cervical variables was compared over time between the reference group and the study group, median CL had increased in the study group (1.47 mm) but it had shortened in the reference group (-2.56 mm). These inverse trends were statistically significant (P = 0.006).
Conclusions: Cervical pessary reduces both uterocervical angles and corrects cervical angulation by pushing the cervix up toward the uterus. Maintaining the cervix aligned to the uterine axis leads to reduced cervical tissue stretch, so avoiding further cervical shortening. All these changes were present after pessary placement; however, the clinical implications of these findings remain unknown.
Keywords: cervical consistency index; cervical length; cervical pessary; preterm birth; transvaginal ultrasound; uterocervical angle.
© 2019 Nordic Federation of Societies of Obstetrics and Gynecology.
Similar articles
-
Prediction of preterm birth and adverse perinatal outcomes after cervical pessary placement in singleton pregnancies with short cervical length.J Matern Fetal Neonatal Med. 2021 Oct;34(19):3147-3153. doi: 10.1080/14767058.2019.1678137. Epub 2019 Oct 23. J Matern Fetal Neonatal Med. 2021. PMID: 31640496
-
Prevention of preterm birth with pessary in twins (PoPPT): a randomized controlled trial.Ultrasound Obstet Gynecol. 2017 May;49(5):567-572. doi: 10.1002/uog.17430. Ultrasound Obstet Gynecol. 2017. PMID: 28170117 Clinical Trial.
-
Arabin cervical pessary in women at high risk of preterm birth: a magnetic resonance imaging observational follow-up study.Ultrasound Obstet Gynecol. 2013 Oct;42(4):426-33. doi: 10.1002/uog.12507. Ultrasound Obstet Gynecol. 2013. PMID: 23671013
-
[Use of pessaries to prevent preterm birth: Are we going back to mechanical devices in obstetrics?].J Gynecol Obstet Biol Reprod (Paris). 2015 Oct;44(8):776-80. doi: 10.1016/j.jgyn.2015.06.013. Epub 2015 Jun 29. J Gynecol Obstet Biol Reprod (Paris). 2015. PMID: 26139034 Review. French.
-
Prediction of preterm birth: cervical sonography.Semin Perinatol. 2009 Oct;33(5):317-24. doi: 10.1053/j.semperi.2009.06.007. Semin Perinatol. 2009. PMID: 19796729 Review.
Cited by
-
Risk factors of early spontaneous preterm birth despite carrying a cervical pessary in singleton pregnancies with a short cervix: Development of a risk prediction model.Eur J Obstet Gynecol Reprod Biol X. 2024 Mar 27;22:100305. doi: 10.1016/j.eurox.2024.100305. eCollection 2024 Jun. Eur J Obstet Gynecol Reprod Biol X. 2024. PMID: 38595705 Free PMC article.
-
Prevention of Preterm Birth by Cervical Pessary Combined with Vaginal Progesterone: a Systematic Review and Meta-analysis with Trial Sequential Analysis.Reprod Sci. 2023 Jan;30(1):93-110. doi: 10.1007/s43032-022-00926-x. Epub 2022 Mar 29. Reprod Sci. 2023. PMID: 35352330 Free PMC article.
References
REFERENCES
-
- Iams JD, Goldenberg RL, Meis PJ, et al. The length of the cervix and the risk of spontaneous delivery. N Engl J Med. 1996;334:567-572.
-
- To MS, Alfirevic Z, Heath VC, et al. Cervical cerclage for prevention of preterm delivery in women with short cervix: randomised controlled trial. Lancet. 2004;363:1849-1853.
-
- Hassan SS, Romero R, Vidyadhari D, et al.; for the PREGNANT Trial. Vaginal progesterone reduces the rate of preterm birth in women with a sonographic short cervix: a multicenter, randomized, double-blind, placebo-controlled trial. Ultrasound Obstet Gynecol. 2011;38:18-31.
-
- Goya M, Pratcorona L, Merced C, et al.; Pesario Cervical para Evitar Prematuridad (PECEP) Trial Group. Cervical pessary in pregnant women with a short cervix (PECEP): an open-label randomised controlled trial. Lancet. 2012;379:1800-1806.
-
- Pratcorona L, Goya M, Merced C, et al.; PECEP-Retard Trial Group. Cervical pessary to reduce preterm birth <34 weeks of gestation after an episode of preterm labor and a short cervix: a randomized controlled trial. Am J Obstet Gynecol. 2018;219:99.e1-99.e16.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical