Improving resolution of head and neck CTA using the small x-ray tube focal spot
- PMID: 31104077
- DOI: 10.1007/s00234-019-02221-0
Improving resolution of head and neck CTA using the small x-ray tube focal spot
Abstract
CT-resolution depends on tube focal spot size. To investigate the effect of reducing focal spot on vessel wall clarity, 22 patients underwent head and neck CTA acquisition with large and small focal spot size. Hounsfield density profile was assessed for each head and neck vessel separately, and significantly sharper density increase at vessel borders was observed using smaller tube focus by an average of 9.9% to 82° angle degrees (p < .05). In conclusion, spatial resolution of CTA of head and neck vessels can be improved by using the small x-ray tube focal spot.
Keywords: Arteries; Cerebral angiography; Computed tomography angiography; Neck; Radiographic image enhancement.
Similar articles
-
Dual-Energy Computed Tomography Angiography of the Head and Neck With Single-Source Computed Tomography: A New Technical (Split Filter) Approach for Bone Removal.Invest Radiol. 2016 Oct;51(10):618-23. doi: 10.1097/RLI.0000000000000290. Invest Radiol. 2016. PMID: 27187046
-
Efficacy of fine focal spot technique in CT angiography of neck.Br J Radiol. 2019 Aug;92(1100):20190083. doi: 10.1259/bjr.20190083. Epub 2019 Jun 20. Br J Radiol. 2019. PMID: 31112401 Free PMC article.
-
Enhancing acute stroke assessment: evaluating the clinical utility of the "Real" one-stop-shop scan protocol combining brain computed tomography perfusion and head-and-neck computed tomography angiography using a 512-slice detector computed tomography scanner.Clin Radiol. 2024 Nov;79(11):833-841. doi: 10.1016/j.crad.2024.07.023. Epub 2024 Aug 6. Clin Radiol. 2024. PMID: 39198108 Clinical Trial.
-
Computed Tomography Angiography of the Neurovascular Circulation.Radiol Clin North Am. 2016 Jan;54(1):147-62. doi: 10.1016/j.rcl.2015.09.001. Radiol Clin North Am. 2016. PMID: 26654397 Review.
-
Computed Tomography Angiography in Head and Neck Emergencies.Semin Ultrasound CT MR. 2017 Aug;38(4):345-356. doi: 10.1053/j.sult.2017.02.003. Epub 2017 Feb 20. Semin Ultrasound CT MR. 2017. PMID: 28865525 Review.
Cited by
-
An Increased Diagnostic Accuracy of Significant Coronary Artery Stenosis Using 320-slice Computed Tomography with Model-based Iterative Reconstruction in Cases with Severely Calcified Coronary Arteries.Intern Med. 2023 Jan 15;62(2):169-176. doi: 10.2169/internalmedicine.9509-22. Epub 2022 Jun 7. Intern Med. 2023. PMID: 35676040 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources