Radiographic Reference Values for the Cardiac Silhouette in Bonelli's Eagle (Aquila fasciata)
- PMID: 31124612
- DOI: 10.1647/2017-318
Radiographic Reference Values for the Cardiac Silhouette in Bonelli's Eagle (Aquila fasciata)
Abstract
Radiographs are an important diagnostic tool available in wildlife hospitals to evaluate the size of the avian heart. Despite the large variety wild birds in the Iberian peninsula, clinical studies addressing these species are lacking. To establish reference values for cardiac size in the Bonelli's eagle (Aquila fasciata), ventrodorsal radiographs of 20 healthy birds were obtained, and the width of the cardiac silhouette, sternum, thorax, coracoid, and hepatic silhouette were measured. The ratios between cardiac width and other mentioned indices were calculated. Results showed that cardiac silhouette width should occupy 81%-93% of sternal width, 48%-57% of thoracic width, and 506%-673% of coracoid width. The cardiac silhouette width was strongly correlated with sternal and thoracic widths. A moderate correlation was found between the width of the heart and the width of the coracoid. No significant correlation was found between width of the cardiac silhouette and the hepatic silhouette. These results support that sternal and thoracic widths should be used preferentially when evaluating the width of the cardiac silhouette in this species. The values obtained in this study can be used as a reference for normal cardiac size when evaluating radiographs of Bonelli's eagles.
Keywords: Aquila fasciata; Bonelli's eagle; avian; cardiac measurements; cardiac silhouette; heart; radiograph; reference values.
© 2019 by the Association of Avian Veterinarians.
Similar articles
-
Radiographic Reference Intervals of the Cardiac Silhouette Width in the Bald Eagle (Haliaeetus leucocephalus).J Avian Med Surg. 2020 Oct 20;34(3):260-267. doi: 10.1647/1082-6742-34.3.260. J Avian Med Surg. 2020. PMID: 33099979
-
Measurement of the cardiac silhouette in psittacines.J Am Vet Med Assoc. 2002 Jul 1;221(1):76-9. doi: 10.2460/javma.2002.221.76. J Am Vet Med Assoc. 2002. PMID: 12420828
-
Haematological and biochemical reference values for Bonelli's eagles in the wild and in captivity: implications for conservation and rehabilitation programs.BMC Vet Res. 2025 May 15;21(1):342. doi: 10.1186/s12917-025-04790-0. BMC Vet Res. 2025. PMID: 40375246 Free PMC article.
-
Cardiac silhouette findings and mediastinal lines and stripes: radiograph and CT scan correlation.Chest. 2011 May;139(5):1186-1196. doi: 10.1378/chest.10-0660. Chest. 2011. PMID: 21540217 Review.
-
The cardiac silhouette.J Thorac Imaging. 2000 Oct;15(4):230-42. doi: 10.1097/00005382-200010000-00003. J Thorac Imaging. 2000. PMID: 11039611 Review.
Cited by
-
Radiographic Measurements of the Cardiac Silhouette and Comparison with Other Radiographic Landmarks in Wild Galahs (Eolophus roseicapilla).Animals (Basel). 2021 Feb 24;11(3):587. doi: 10.3390/ani11030587. Animals (Basel). 2021. PMID: 33668166 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources