Isotopic Ratio Outlier Analysis (IROA) for Quantitative Analysis
- PMID: 31127543
- DOI: 10.1007/978-1-4939-9488-5_2
Isotopic Ratio Outlier Analysis (IROA) for Quantitative Analysis
Abstract
There is always a tension within the omics sciences between trying to measure biological molecules rapidly and measuring accurately. Metabolomics as an omics science tries to measure the small biochemicals rapidly, in a single pass, but the current state of the art cannot provide the reproducibility or accuracy needed for clinical use or even daily reproducibility for larger experiments. The IROA TruQuant measurement system uses a daily "Long-Term Reference Standard (LTRS)" and a chemically identical Internal Standard (IS) to provide validated chemical identity, daily QA/QC on instrument and sample preparation, and accurate reproducible quantitation that is comparable across days, instruments, and even, for most compounds, chromatographic methods. The LTRS is, as the name implies, a Long-Term Reference Standard that is always the same and should therefore provide very similar results on a large but finite collection of compounds. All of the compounds in the LTRS are isotopically signed with formula indicating IROA patterns so they cannot be mistaken for one another. Because of the precise IROA patterns, a software-driven analysis of the compounds seen daily can determine the performance of the instrument in terms of sensitivity, in-source fragmentation, and chromatographic and injection stability and provide completely reproducible quantitation.
Keywords: IROA patterns; Internal Standard (IS); Long-Term Reference Standard (LTRS); Quality assurance/quality control (QA/QC); Reproducible quantitation.
Similar articles
-
Isotopic Ratio Outlier Analysis (IROA) for Quantitative Analysis.Methods Mol Biol. 2025;2925:69-89. doi: 10.1007/978-1-0716-4534-5_4. Methods Mol Biol. 2025. PMID: 40498181
-
Quantitative Metabolomics Using Isotope Residue Outlier Analysis (IROA®) with Internal Standards.Methods Mol Biol. 2019;1996:41-46. doi: 10.1007/978-1-4939-9488-5_4. Methods Mol Biol. 2019. PMID: 31127545
-
Isotopic Ratio Outlier Analysis (IROA) of Aqueous Humor for Metabolites.Methods Mol Biol. 2019;1996:179-185. doi: 10.1007/978-1-4939-9488-5_15. Methods Mol Biol. 2019. PMID: 31127556
-
Ensuring the reliability of stable isotope ratio data--beyond the principle of identical treatment.Anal Bioanal Chem. 2013 Mar;405(9):2799-814. doi: 10.1007/s00216-012-6551-0. Epub 2012 Dec 30. Anal Bioanal Chem. 2013. PMID: 23274555 Review.
-
Stable isotope coded derivatizing reagents as internal standards in metabolite profiling.J Chromatogr A. 2013 Jun 28;1296:196-203. doi: 10.1016/j.chroma.2013.03.072. Epub 2013 Apr 9. J Chromatogr A. 2013. PMID: 23628173 Review.
Cited by
-
Combining Isotopologue Workflows and Simultaneous Multidimensional Separations to Detect, Identify, and Validate Metabolites in Untargeted Analyses.Anal Chem. 2022 Feb 8;94(5):2527-2535. doi: 10.1021/acs.analchem.1c04430. Epub 2022 Jan 28. Anal Chem. 2022. PMID: 35089687 Free PMC article.
-
Differentiation of soluble aqueous humor metabolites in primary open angle glaucoma and controls.Exp Eye Res. 2020 May;194:108024. doi: 10.1016/j.exer.2020.108024. Epub 2020 Apr 1. Exp Eye Res. 2020. PMID: 32246983 Free PMC article.
-
Correction: Fadil et al. Isotope Ratio Outlier Analysis (IROA) for HPLC-TOFMS-Based Metabolomics of Human Urine. Metabolites 2022, 12, 741.Metabolites. 2024 May 23;14(6):293. doi: 10.3390/metabo14060293. Metabolites. 2024. PMID: 38921481 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources