Triacetone triperoxide characterization by FT-ICR mass spectrometry: Uncovering multiple forensic evidence
- PMID: 31128407
- DOI: 10.1016/j.forsciint.2019.04.020
Triacetone triperoxide characterization by FT-ICR mass spectrometry: Uncovering multiple forensic evidence
Abstract
Triacetone triperoxide is one of the most common used explosives by terrorist and criminal groups, being easily synthesized with over the counter reagents. Moreover, it's difficult to detect since it contains no nitrogen. Extreme resolution mass spectrometry, based on Fourier transform ion cyclotron resonance mass spectrometry provides a way to established its composition, being able to detect its presence in complex matrixes. In this work, we investigated the detailed chemical composition of triacetone triperoxide and analysed latent fingerprints for evidence of its handling. Our results allowed the characterization of the oligoperoxides formed in the synthesis of triacetone triperoxide: oligomers dihydroperoxy terminated [H(OOC(CH3)2)nOOH] and the oligomeric acetone carbonyl oxides terminated as hydroperoxides [H(O2C(CH3)2)nOOC(O)CH3]. The discrimination between the different synthetic routes using different acid catalysts is possible given the clear differences between the mass spectrum corresponding to each case. Moreover, we identified triacetone triperoxide in latent fingerprints following its manipulation. For criminal investigation, in addition to the unambiguous detection and identification of the explosive, it is of the highest interest to identify the reagents used, who produced it and who used it for criminal purposes.
Keywords: Explosives; FT-ICR-MS; Fingerprints; TATP.
Copyright © 2019. Published by Elsevier B.V.
Similar articles
-
Characterization of the explosive triacetone triperoxide and detection by ion mobility spectrometry.Forensic Sci Int. 2003 Jul 29;135(1):53-9. doi: 10.1016/s0379-0738(03)00175-0. Forensic Sci Int. 2003. PMID: 12893136
-
Analysis of triacetone triperoxide (TATP) and TATP synthetic intermediates by electrospray ionization mass spectrometry.Rapid Commun Mass Spectrom. 2008;22(2):84-90. doi: 10.1002/rcm.3335. Rapid Commun Mass Spectrom. 2008. PMID: 18058960
-
Detection of Triacetone Triperoxide (TATP) and Hexamethylene Triperoxide Diamine (HMTD) from the Gas Phase with Differential Ion Mobility Spectrometry (DMS).Sensors (Basel). 2021 Jul 2;21(13):4545. doi: 10.3390/s21134545. Sensors (Basel). 2021. PMID: 34283071 Free PMC article.
-
Towards analytically useful two-dimensional Fourier transform ion cyclotron resonance mass spectrometry.Anal Bioanal Chem. 2013 Jan;405(1):51-61. doi: 10.1007/s00216-012-6422-8. Epub 2012 Oct 18. Anal Bioanal Chem. 2013. PMID: 23076397 Review.
-
Screening of synthetic PDE-5 inhibitors and their analogues as adulterants: analytical techniques and challenges.J Pharm Biomed Anal. 2014 Jan;87:176-90. doi: 10.1016/j.jpba.2013.04.037. Epub 2013 May 6. J Pharm Biomed Anal. 2014. PMID: 23721687 Review.
Cited by
-
Interpol review of the analysis and detection of explosives and explosives residues.Forensic Sci Int Synerg. 2023 Jan 13;6:100298. doi: 10.1016/j.fsisyn.2022.100298. eCollection 2023. Forensic Sci Int Synerg. 2023. PMID: 36685733 Free PMC article. Review. No abstract available.
-
Interpol review of fingermarks and other body impressions 2016-2019.Forensic Sci Int Synerg. 2020 Mar 17;2:442-480. doi: 10.1016/j.fsisyn.2020.01.013. eCollection 2020. Forensic Sci Int Synerg. 2020. PMID: 33385142 Free PMC article. Review.
LinkOut - more resources
Full Text Sources