Comparison of Flow Diversion and Coiling for the Treatment of Unruptured Intracranial Aneurysms
- PMID: 31132489
- DOI: 10.1016/j.wneu.2019.05.149
Comparison of Flow Diversion and Coiling for the Treatment of Unruptured Intracranial Aneurysms
Abstract
Background: To systematically assess the efficacy and safety between flow diversion and coiling for patients with unruptured intracranial aneurysms.
Methods: Potential academic articles were identified from Cochrane Library, Medline, PubMed, EMBASE, ScienceDirect, and other databases. The time range we retrieved from was the inception of electronic databases to February 2019. Gray studies were identified from the references of included literature reports. STATA version 11.0 was used to analyze the pooled data.
Results: A total of 11 articles (10 retrospective studies and 1 prospective study) were involved in our study. The overall participants of the coiling group were 611, whereas 576 were in the flow diversion group. Our meta-analysis showed that flow diversion was preferable for unruptured intracranial aneurysms as its lower value of total cost per case (weighted mean difference, 5705.906; 95% confidence interval [CI], [4938.536, 6473236]; P < 0.001), fluoroscopy time per case (weighted mean difference, 25.786; 95% CI, 17.169-34.377; P < 0.001), and retreatment rates (odds ratio [OR], 7.127; 95% CI, [3.525, 14.410]; P < 0.001), at the same time, a higher rate of immediate completed occlusion (OR, 0.390; 95% CI, [0.224, 0.680]; P = 0.001) and follow-up completed occlusion (OR, 0.173; 95% CI, [0.080, 0.375]; P < 0.001) was demonstrated in the flow diversion group. There was no difference on intraoperative complication rates (P = 0.070), procedure-related mortality (P = 0.609) and rupture rates (P = 0.408), modified Rankin Scale (mRS) 0-2 at discharge (P = 0.077), and mRS 0-2 at follow-up (P = 0.484).
Conclusions: The use of flow diversion for the treatment of unruptured intracranial aneurysms may reduce total cost per case, fluoroscopy time per case, retreatment rates, and increases immediate completed occlusion and follow-up completed occlusion rates without affecting the results of mRS and intraoperative complication.
Keywords: Balloon-assisted coiling; Flow diversion; Meta-analysis; Stent-assisted coiling; Unruptured intracranial aneurysms.
Copyright © 2019 Elsevier Inc. All rights reserved.
Similar articles
-
Residuals, recurrences and re-treatment after endovascular repair of intracranial aneurysms: A retrospective methodological comparison.Interv Neuroradiol. 2020 Feb;26(1):45-54. doi: 10.1177/1591019919867841. Epub 2019 Aug 12. Interv Neuroradiol. 2020. PMID: 31403834 Free PMC article.
-
Evaluation of ischemic lesion prevalence after endovascular treatment of intracranial aneurysms, as documented by 3-T diffusion-weighted imaging: a 2-year, single-center cohort study.J Neurosurg. 2018 Apr;128(4):982-991. doi: 10.3171/2016.11.JNS161020. Epub 2017 Jun 9. J Neurosurg. 2018. PMID: 28598274
-
Analysis of cerebrovascular aneurysm treatment cost: retrospective cohort comparison of clipping, coiling, and flow diversion.Neurosurg Focus. 2018 May;44(5):E3. doi: 10.3171/2018.1.FOCUS17775. Neurosurg Focus. 2018. PMID: 29712525
-
Flow-Diversion Treatment of Unruptured Saccular Anterior Communicating Artery Aneurysms: A Systematic Review and Meta-Analysis.AJNR Am J Neuroradiol. 2019 Mar;40(3):497-502. doi: 10.3174/ajnr.A5967. Epub 2019 Feb 14. AJNR Am J Neuroradiol. 2019. PMID: 30765379 Free PMC article.
-
Distal anterior cerebral artery aneurysms treated with flow diversion: experience of a large-volume center and systematic review of the literature.J Neurointerv Surg. 2021 Jan;13(1):42-48. doi: 10.1136/neurintsurg-2020-015980. Epub 2020 May 26. J Neurointerv Surg. 2021. PMID: 32457222
Cited by
-
Effects of stent-assisted coiling in comparison with flow diversion on intracranial aneurysms.Front Neurol. 2022 Nov 8;13:937536. doi: 10.3389/fneur.2022.937536. eCollection 2022. Front Neurol. 2022. PMID: 36425805 Free PMC article.
-
Comparison of Molecular Methods and BRAF Immunohistochemistry (VE1 Clone) for the Detection of BRAF V600E Mutation in Papillary Thyroid Carcinoma: A Meta-Analysis.Head Neck Pathol. 2020 Dec;14(4):1067-1079. doi: 10.1007/s12105-020-01166-8. Epub 2020 May 1. Head Neck Pathol. 2020. PMID: 32358715 Free PMC article.
-
Vascular Response on a Novel Fibrin-Based Coated Flow Diverter.Cardiovasc Intervent Radiol. 2022 Feb;45(2):236-243. doi: 10.1007/s00270-021-03007-9. Epub 2021 Dec 16. Cardiovasc Intervent Radiol. 2022. PMID: 34913987 Free PMC article.
-
Effects of the flow diversion technique on nucleotide levels in intra-cranial aneurysms: A feasibility study providing new research perspectives.Front Cardiovasc Med. 2022 Sep 14;9:885426. doi: 10.3389/fcvm.2022.885426. eCollection 2022. Front Cardiovasc Med. 2022. PMID: 36186973 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical