The value of the left atrial appendage orifice perimeter of 3D model based on 3D TEE data in the choice of device size of LAmbre™ occluder
- PMID: 31134413
- DOI: 10.1007/s10554-019-01627-4
The value of the left atrial appendage orifice perimeter of 3D model based on 3D TEE data in the choice of device size of LAmbre™ occluder
Abstract
Preoperative optimal selection of the occluder size is crucial in percutaneous left atrial appendage (LAA) occlusion, and the maximal width of the LAA orifice is the main reference index, however it can not fully meet the practical operation requirements. We retrospectively analyzed three-dimensional (3D) transesophageal echocardiography (TEE) and computed tomography (CT) imaging dataset of the 41 patients who underwent LAA occlusion with LAmbre™ system. The LAA orifice parameters were overall evaluated to determine their role in device size selection. Eight LAA 3D models of the four cases who had been replaced their device during the procedure based on TEE and CT were printed out to verify the optimal parameter decision strategy. There was a significant concordance of the results between 3D TEE and CT in the LAA orifice evaluation. The correlations between the perimeter and maximal width measurements by 3D TEE and the closure disk of the device were stronger than that between the area measurements and the closure disk (r = 0.93, 0.95, 0.86, respectively and p < 0.001 all), and the result was similar to that by CT (r = 0.92, 0.93, 0.84, respectively and p < 0.001 all). The ratios of the maximal width to the minimal width of the four cases were all > 1.4, however the rest 37 cases were all ≤ 1.4. Based on the comprehensive assessment of the LAA orifice perimeter and maximal width of the 3D printed models, the experiments were all succeed just for one try. The LAA orifice perimeter of 3D printed model based on 3D TEE may help in choosing the optimal device size of LAmbre™, especially for the LAA with flater ostial shape.
Keywords: Computed tomography; Left atrial appendage closure; Orifice; Size; Three-dimensional model; Three-dimensional transesophageal echocardiography.
Similar articles
-
Cardiac CT Angiography (CCTA) predicts left atrial appendage occluder device size and procedure outcome.Int J Cardiovasc Imaging. 2017 May;33(5):739-747. doi: 10.1007/s10554-016-1050-6. Epub 2017 Jan 9. Int J Cardiovasc Imaging. 2017. PMID: 28070743
-
Interventional left atrial appendage occlusion: added value of 3D transesophageal echocardiography for device sizing.Int J Cardiovasc Imaging. 2016 Sep;32(9):1363-1370. doi: 10.1007/s10554-016-0923-z. Epub 2016 Jun 6. Int J Cardiovasc Imaging. 2016. PMID: 27271934
-
CT based 3D printing is superior to transesophageal echocardiography for pre-procedure planning in left atrial appendage device closure.Int J Cardiovasc Imaging. 2018 May;34(5):821-831. doi: 10.1007/s10554-017-1289-6. Epub 2017 Dec 8. Int J Cardiovasc Imaging. 2018. PMID: 29222738
-
Systematic review on left atrial appendage closure with the LAmbre device in patients with non-valvular atrial fibrillation.BMC Cardiovasc Disord. 2020 Feb 12;20(1):78. doi: 10.1186/s12872-020-01349-9. BMC Cardiovasc Disord. 2020. PMID: 32050904 Free PMC article.
-
Role of cardiac imaging and three-dimensional printing in percutaneous appendage closure.Arch Cardiovasc Dis. 2018 Jun-Jul;111(6-7):411-420. doi: 10.1016/j.acvd.2018.04.005. Epub 2018 Jun 7. Arch Cardiovasc Dis. 2018. PMID: 29886007 Review.
Cited by
-
Preprocedural Planning of Left Atrial Appendage Occlusion: A Review of the Use of Additive Manufacturing.3D Print Addit Manuf. 2024 Feb 1;11(1):333-346. doi: 10.1089/3dp.2022.0373. Epub 2024 Feb 15. 3D Print Addit Manuf. 2024. PMID: 38389681 Free PMC article. Review.
-
Virtual reality utilization for left atrial appendage occluder device size prediction.Heliyon. 2023 Apr 4;9(4):e14790. doi: 10.1016/j.heliyon.2023.e14790. eCollection 2023 Apr. Heliyon. 2023. PMID: 37089380 Free PMC article.
-
Pre-procedural determination of device size in left atrial appendage occlusion using three-dimensional cardiac computed tomography.Sci Rep. 2021 Dec 16;11(1):24107. doi: 10.1038/s41598-021-03537-9. Sci Rep. 2021. PMID: 34916575 Free PMC article.
References
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical