. 2019 Jul;26(21):21750-21759.
doi: 10.1007/s11356-019-05375-9. Epub 2019 May 27.

Exposure to inhalable aerosols and their chemical characteristics from different potential factors in urban office environments

Affiliations

Exposure to inhalable aerosols and their chemical characteristics from different potential factors in urban office environments

Hyeon-Ju Oh et al. Environ Sci Pollut Res Int. 2019 Jul.

Abstract

Indoor air quality (IAQ) is one of important issues in indoor environment due to exposure to inhalable aerosol which is affected by indoor and outdoor factors. To demonstrate the effect of indoor and outdoor to the IAQ, this study presents three fractions of particulate matter (PM) (PM2.5, PM4, PM10), characterization of I/O ratios for PM under potential indoor (average occupancy) and outdoor factors (Asian dust, rain, wind, and snow days) and evaluation of chemical components in aerosols. In the chemical characteristics of PM, organic carbon (OC), elemental carbon (EC), and trace elements were analyzed in indoors and outdoors. There was no significant difference of respirable aerosol (PM2.5 and PM4) concentration in different indoor environments. The concentration of OC in PM10 was lower in indoor than outdoor in summer and winter seasons, while the concentration of OC in PM2.5 was higher in indoor than outdoor. Also, the OC/EC ratios in PM2.5 were higher than those in PM10. Further, the ratios of trace elements in PM2.5 and PM10 were different at various locations within the building. This study demonstrated that the exposure to PM2.5 is greatly affected by outdoor environment. Although there was no difference in inhalable and respirable aerosol concentration at different locations within the building, the impact of outdoor factors is strongly supported by OC/EC ratios and PM2.5/PM10 ratios of trace elements. This study shows that chemical components through the HVAC system affected the exposure to the indoor respirable aerosol, which could lead to adverse effect on the indoor air quality.

Keywords: Carbonaceous aerosol; Exposure to indoor PM; HVAC system; Inhalable aerosol; Respirable aerosol; Trace element.

PubMed Disclaimer

Similar articles

References

    1. Indoor Air. 2003 Jun;13(2):96-105 - PubMed
    1. Chemosphere. 2005 Jul;60(3):355-64 - PubMed
    1. Sci Total Environ. 2006 Jul 31;366(1):124-35 - PubMed
    1. Environ Monit Assess. 2006 Aug;119(1-3):425-39 - PubMed
    1. Sci Total Environ. 2007 Sep 1;382(2-3):228-39 - PubMed

LinkOut - more resources