Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?
- PMID: 31136427
- PMCID: PMC6554106
- DOI: 10.1097/CORR.0000000000000710
Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?
Abstract
Background: Hooded acetabular liners and head sizes ≥ 32 mm have both shown to have a beneficial effect on the revision rate for dislocation in THA. Experience with noncrosslinked polyethylene (nonXLPE) raised concerns regarding the risk of impingement damage, loosening, and osteolysis with hooded liners; however, the evidence for this in crosslinked polyethylene (XLPE) is inconclusive. The interaction between different femoral head sizes and hooded liners is not well understood, and it is unclear whether hooded XLPE liners have a beneficial effect on overall long-term survivorship.
Questions/purposes: We analyzed a large national joint registry to ask: (1) Is the use of hooded XLPE liners associated with a reduced revision rate for dislocation compared with nonhooded liners? (2) Is there a difference in the revision rate for aseptic loosening/osteolysis? (3) Is head size associated with any difference in the revision rate between hooded and nonhooded liners?
Methods: The Australian Orthopaedic Association National Joint Replacement Registry longitudinally maintains data on all primary and revision joint arthroplasties with nearly 100% capture. We analyzed all conventional primary THAs performed from registry inception in September 1999 until December 31, 2016 in patients with a diagnosis of osteoarthritis who had nonhooded or hooded XLPE bearings in a cementless acetabular shell. The study group included 192,659 THA procedures with XLPE liners, of which 67,904 were nonhooded and 124,755 were hooded. The mean age of patients receiving nonhooded liners was 70 years (range, 11-100 years); 44% were males. This was similar to the patients with hooded liners, who had a mean age of 70 years (range, 16-100 years); 45% were males. The main outcome measure was the cumulative percent revision at 15 years of the THA using Kaplan-Meier estimates of survivorship. We examined reasons for revision and and performed multivariable analysis to control for the confounding factors of three head size groups (< 32mm, 32mm, and > 32mm) and for the method of femoral fixation.
Results: There was a higher revision rate for dislocation for patients with nonhooded liners at all times to 15 years (HR, 1.31; 95% CI, 1.17-1.47; p < 0.001). There was a higher revision rate for the diagnosis of aseptic loosening/osteolysis with patients with nonhooded liners compared with hooded liners (HR, 1.19; 95% CI, 1.05-1.34; p = 0.006). Head sizes of 32 mm or larger were independently associated with a lower comparative revision rate between hooded and nonhooded liners, but this was not apparent for head sizes smaller than 32 mm. It appeared that the main driver of the finding in larger heads was a reduced dislocation risk with hooded liners for 32 mm heads (HR, 1.50; 95% CI, 1.23-1.80; p < 0.001) and for heads larger than 32 mm (HR, 1.50; 95% CI, 1.20-1.89; p < 0.001).
Conclusions: Prior research has suggested that hooded acetabular liners may be associated with impingement, loosening, and osteolysis; however, in this large, registry-based report we found that XLPE hooded liners are not associated with an increased revision rate for aseptic loosening/osteolysis. Although there are many potential confounding variables in this registry analysis, if anything, surgeons using larger femoral heads and hooded liners likely did so in patients with a higher perceived dislocation risk. Patients with larger heads and XLPE hooded liners were, however, less likely to experience revision for dislocation. These liners therefore appear reasonable to use in primary THA at the surgeon's discretion.
Level of evidence: Level III, therapeutic study.
Conflict of interest statement
Each author certifies that he or she has no commercial associations (eg consultancies, stock ownership, equity interest, patent/licensing arrangements etc) that might pose a conflict of interest in connection with the submitted article.
All ICMJE Conflict of Interest Forms for authors and
Figures




Comment in
-
CORR Insights®: Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?Clin Orthop Relat Res. 2019 Jun;477(6):1322-1323. doi: 10.1097/CORR.0000000000000768. Clin Orthop Relat Res. 2019. PMID: 31136428 Free PMC article. No abstract available.
Similar articles
-
In Revision THA, Is the Re-revision Risk for Dislocation and Aseptic Causes Greater in Dual-mobility Constructs or Large Femoral Head Bearings? A Study from the Australian Orthopaedic Association National Joint Replacement Registry.Clin Orthop Relat Res. 2022 Jun 1;480(6):1091-1101. doi: 10.1097/CORR.0000000000002085. Epub 2022 Jan 3. Clin Orthop Relat Res. 2022. PMID: 34978538 Free PMC article.
-
Is the Survivorship of Birmingham Hip Resurfacing Better Than Selected Conventional Hip Arthroplasties in Men Younger Than 65 Years of Age? A Study from the Australian Orthopaedic Association National Joint Replacement Registry.Clin Orthop Relat Res. 2020 Nov;478(11):2625-2636. doi: 10.1097/CORR.0000000000001453. Clin Orthop Relat Res. 2020. PMID: 32898048 Free PMC article.
-
What Is the Outcome of the First Revision Procedure of Primary THA for Osteoarthritis? A Study From the Australian Orthopaedic Association National Joint Replacement Registry.Clin Orthop Relat Res. 2022 Oct 1;480(10):1952-1970. doi: 10.1097/CORR.0000000000002339. Epub 2022 Aug 18. Clin Orthop Relat Res. 2022. PMID: 35980886 Free PMC article.
-
Outcomes of different bearings in total hip arthroplasty - implant survival, revision causes, and patient-reported outcome.Dan Med J. 2017 Mar;64(3):B5350. Dan Med J. 2017. PMID: 28260601 Review.
-
Incidence of Osteolysis and Aseptic Loosening Following Metal-on-Highly Cross-Linked Polyethylene Hip Arthroplasty: A Systematic Review of Studies with Up to 15-Year Follow-up.J Bone Joint Surg Am. 2021 Apr 21;103(8):728-740. doi: 10.2106/JBJS.20.01086. J Bone Joint Surg Am. 2021. PMID: 33411465
Cited by
-
Using an asymmetric crosslinked polyethylene liner in primary total hip arthroplasty is associated with a lower risk of revision surgery : an analysis of the National Joint Registry.Bone Joint J. 2021 Sep;103-B(9):1479-1487. doi: 10.1302/0301-620X.103B9.BJJ-2021-0365.R1. Bone Joint J. 2021. PMID: 34465151 Free PMC article.
-
[Standard and special liner in primary hip arthroplasty : Current study and survey results from the German Arthroplasty Registry (EPRD)].Orthopadie (Heidelb). 2023 Mar;52(3):222-232. doi: 10.1007/s00132-022-04333-7. Epub 2023 Jan 12. Orthopadie (Heidelb). 2023. PMID: 36635446 Review. German.
-
Recent update on crosslinked polyethylene in total hip arthroplasty.SICOT J. 2020;6:13. doi: 10.1051/sicotj/2020013. Epub 2020 May 15. SICOT J. 2020. PMID: 32412408 Free PMC article.
-
Dual mobility versus conventional total hip arthroplasty in femoral neck fractures (DISTINCT): protocol for a registry-nested, open-label, cluster-randomised crossover trial.BMJ Open. 2022 Sep 21;12(9):e064478. doi: 10.1136/bmjopen-2022-064478. BMJ Open. 2022. PMID: 36130765 Free PMC article.
-
CORR Insights®: Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?Clin Orthop Relat Res. 2019 Jun;477(6):1322-1323. doi: 10.1097/CORR.0000000000000768. Clin Orthop Relat Res. 2019. PMID: 31136428 Free PMC article. No abstract available.
References
-
- Amstutz HC, Lodwig RM, Schurman DJ, Hodgson AG. Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus. Clin Orthop Relat Res. 1975;111:124-30 - PubMed
-
- Australian Orthopaedic Association National Joint Replacement Registry. Annual Report. Adelaide: AOA; 2018:15, 135 Available at: https://aoanjrr.sahmri.com/annual-reports-2018 Accessed January 30, 2019.
-
- Biau DJ, Latouche A, Porcher R. Competing events influence estimated survival probability: when is Kaplan-Meier analysis appropriate? Clin Orthop Relat Res. 2007;462:229-233. - PubMed
-
- Brooks PJ. Dislocation following total hip replacement: causes and cures. Bone Joint J. 2013;95-B(11 Suppl A):67-69. - PubMed
-
- Charnley J. Low friction Arthroplasty of the Hip: Theory and Practice. Spinger; New York, 1979:315-316.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials