Amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with a nanocomposite prepared from ferumoxytol and reduced graphene oxide decorated with platinum nanoparticles

Affiliations

Amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with a nanocomposite prepared from ferumoxytol and reduced graphene oxide decorated with platinum nanoparticles

Yuanyuan Zhang et al. Mikrochim Acta. .

Abstract

A high-performance electrochemical H2O2 sensor was prepared by constructing multiple interfaces using platinum nanoparticles (Pt NPs), ferumoxytol (Fer) and reduced graphene oxide (rGO) on a glassy carbon electrode (GCE). The morphology of Fer/rGO and Fer/rGO-Pt was characterized by field emission scanning electron microscopy and energy-dispersive X-ray spectroscopy. Cyclic voltammetry and chronoamperometry were adopted to characterize the electrochemical properties of the sensor. Because of the synergistic catalytic effect of the compositions (rGO, Fer and Pt NPs) on the multiple interfaces, the sensor exhibits particularly high electrocatalytic activity toward the reduction of H2O2 with a low detection limit (~0.38 μM), a linear range (0.0004-0.01, 0.0075-4.3 and 4.9-10.8 mM), and a high sensitivity (340 μA mM-1 cm-2, n = 4) operated at a typical working voltage of +0.1 V (vs. Ag/AgCl). The electrode is selective and long-term stable. It was successfully applied to the determination of H2O2 in (spiked) milk samples. Graphical abstract Schematic presentation of an electrochemical H2O2 sensor using platinum nanoparticles (Pt NPs), ferumoxytol (Fer) and reduced graphene oxide (rGO) nanocomposites modified glassy carbon electrode (GCE). The sensor was applied to the determination of H2O2 in (spiked) milk samples.

Keywords: Amperometric sensor; Chronoamperometry; Cyclic voltammetry; Electrocatalytic activity; Multiple interface; Real sample analysis.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Biosens Bioelectron. 2011 Apr 15;26(8):3614-9 - PubMed
    1. Analyst. 2012 Jan 7;137(1):49-58 - PubMed
    1. Biosens Bioelectron. 2009 Jul 15;24(11):3264-8 - PubMed
    1. Biosens Bioelectron. 2011 Jun 15;26(10):4012-7 - PubMed
    1. Adv Mater. 2010 May 18;22(19):2206-10 - PubMed

Publication types