Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2019 Jun;69(6):1801-1806.
doi: 10.1016/j.jvs.2018.07.078.

Long-term impact of the Vascular Study Group of New England carotid patch quality initiative

Affiliations
Free article
Multicenter Study

Long-term impact of the Vascular Study Group of New England carotid patch quality initiative

Leia Edenfield et al. J Vasc Surg. 2019 Jun.
Free article

Abstract

Objective: Patch angioplasty has been shown to decrease rates of restenosis after carotid endarterectomy (CEA). In 2003, the Vascular Study Group of New England (VSGNE) implemented its first quality initiative aimed at increasing the rates of patch closure after CEA. This study reports the effects of that initiative on the rate of patch closure in the VSGNE and also postoperative and 1-year CEA outcomes.

Methods: Patients undergoing CEA (N = 14,636) within the VSGNE between 2003 and 2014 were studied. Rates of in-hospital postoperative events (death, ipsilateral stroke or transient ischemic attack [TIA], and return to the operating room for bleeding) and events during 1 year of follow-up (stroke or TIA and restenosis >70% or occlusion) were compared by repair type-patch closure, primary closure, or eversion. One-year follow-up events were also compared over time and by annualized surgeon volume.

Results: During the 12 years studied, patch use increased from 71% to 91% (P < .001). There was no difference in postoperative death or ipsilateral stroke or TIA between the repair types. However, there was a statistically lower rate of return to the operating room for bleeding (P < .001), 1-year stroke or TIA (P < .003), and 1-year restenosis or occlusion (P < .001) with patch closure. Overall, the rates of 1-year stroke or TIA and restenosis decreased over time in the VSGNE. The initiative affected patch closure rates and outcomes of high-volume surgeons (>47 CEAs/y) the most. High-volume surgeons increased patch use from 50% to 90% and decreased their restenosis rates from 9.0% to 1.2% and 1-year stroke or TIA from 4.9% to 1.9% (P < .001).

Conclusions: The VSGNE carotid patch quality initiative successfully increased the rates of CEA patch closure. During the same time, there has been a decrease in postoperative bleeding requiring reoperation and 1-year ipsilateral neurologic events and restenosis or occlusion.

Keywords: Carotid; Endarterectomy; Quality initiative; Stroke.