Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1987 Sep;25(9):1641-4.
doi: 10.1128/jcm.25.9.1641-1644.1987.

Murine monoclonal antibodies for detection of antigens and culture identification of Neisseria meningitidis group B and Escherichia coli K-1

Affiliations

Murine monoclonal antibodies for detection of antigens and culture identification of Neisseria meningitidis group B and Escherichia coli K-1

E Krambovitis et al. J Clin Microbiol. 1987 Sep.

Abstract

Four murine monoclonal antibodies which reacted with a (2----8)alpha-linked sialic acid polysaccharide were produced. Three of the antibodies reacted specifically with Neisseria meningitidis serogroup B and Escherichia coli K-1 polysaccharide antigens, whereas one antibody cross-reacted with N. meningitidis group C polysaccharide antigen, a (2----9)alpha-linked homopolymer of sialic acid. By using the most avid antibody (MB 62), a latex particle agglutination test was developed which could detect capsular polysaccharide at 10 ng/ml. It also detected antigen in the cerebrospinal fluid (CSF) of all seven N. meningitidis group B- and two E. coli K-1-infected patients, whereas 57 control CSF samples, including 8 from neonates, were negative. Cultures of 21 N. meningitidis group B strains, 7 E. coli K-1 strains, and 1 Moraxella nonliquefaciens strain gave a positive result, whereas 53 strains from other serogroups were all negative. In a separate clinical evaluation, the overall sensitivity of the latex particle agglutination test was 81% (22 of 27) with fresh CSF samples, 48% (15 of 31) with stored CSF samples, and 94% (32 of 34) with blood cultures. No false-positive reactions were recorded with 165 control CSF samples, and the specificity with blood cultures was 99.4% (519 of 522).

PubMed Disclaimer

References

    1. J Biol Chem. 1985 Jan 25;260(2):1265-70 - PubMed
    1. Carbohydr Res. 1984 Oct 1;133(1):59-74 - PubMed
    1. Carbohydr Res. 1984 Dec 1;134(2):229-43 - PubMed
    1. Carbohydr Res. 1986 Nov 15;156:123-35 - PubMed
    1. Lancet. 1972 May 27;1(7761):1154-7 - PubMed

MeSH terms

Substances

LinkOut - more resources