. 2019 Oct;41(5):601-606.
doi: 10.1111/ijlh.13069. Epub 2019 Jun 4.

Blast flagging of the Sysmex XN-10 hematology analyzer with supervised cell image analysis: Impact on quality parameters

Affiliations

Blast flagging of the Sysmex XN-10 hematology analyzer with supervised cell image analysis: Impact on quality parameters

Jessica Petrone et al. Int J Lab Hematol. 2019 Oct.

Abstract

Introduction: The Sysmex XN-10 automated hematology analyzer (Sysmex Corporation) is routinely used in hematology laboratories to perform complete blood cell count with differential (CBC w/ diff). The sensitivity of this system for blast detection is unclear, since many prior studies evaluating the blast flagging capabilities of Sysmex XN series used the white precursor cell (WPC) channel, which is not cleared for use in the United States.

Methods: We assessed the blast flagging capabilities of the Sysmex XN-10 compared with CellaVision (a cell image analyzer)-assisted visual hematology results. We evaluated the following flags: "blasts?/abnormal lymph?" and "immature granulocytes present" and compared differences in turnaround time between methods.

Results: We collected data on 2239 CBC w/ diff Sysmex automated analyzer differential and CellaVision-assisted visual differential from the inpatient hematology-oncology population of a tertiary care medical center. Solely analyzing the first CBC/diff from each unique patient, both flags had a combined sensitivity of 100%, specificity of 50.2%, PPV of 21.7%, and NPV of 100%. The mean turnaround time for the automated differential was 19.5 minutes (SD 35.9 minutes) compared with 66.4 minutes for the CellaVision-assisted visual differential (SD 68.5 minutes; P < 0.001; Figure 1).

Conclusion: The Sysmex XN-10 abnormal lymphocyte/blast and immature granulocytes flags had excellent sensitivity and acceptable specificity in detecting circulating blasts with shorter turnaround time than the CellaVision-assisted visual differential. Our study suggests that automated differentials performed on Sysmex XN-10 can replace visual differentials as a first-line screening method for blast detection with improved turnaround time in hematology-oncology populations.

Keywords: Cellavision; Sysmex XN; blast; cell image analysis; leukemia.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. Ryan DH. Examination of blood cells. In Kaushansky K, Lichtman MA, Prchal JT, Levi MM, Press OW, Burns LJ, Caligiuri M, eds. Williams Hematology (9th edn). New York, NY: McGraw-Hill; 2016:11-26.
    1. Vajpayee N, Graham S, Bem S. Basic examination of blood and bone marrow. In McPherson R, Pincus M, eds. Henry's Clinical Diagnosis and Management by Laboratory Methods (23rd edn). St. Louis, MO: Elsevier; 2017:510-539.
    1. Briggs CJ, Linssen J, Longair I, Machin SJ. Improved flagging rates on the Sysmex XE-5000 compared with the XE-2100 Reduce the number of manual film reviews and increase laboratory productivity. Am J Clin Pathol. 2011;136:309-316.
    1. Hotton J, Broothaers J, Swaelens C, Cantinieaux B. Performance and abnormal cell flagging comparisons of three automated blood cell counters. Am J Clin Pathol. 2013;140:845-852.
    1. Eilertsen H, Hagve T. Do the flags related to immature granulocytes reported by the Sysmex XE-5000 warrant a microscopic slide review? Am J Clin Pathol. 2014;142:553-560.

MeSH terms