. 2019 Nov;47(11):2271-2283.
doi: 10.1007/s10439-019-02293-2. Epub 2019 Jun 4.

In Vitro Study of Particle Transport in Successively Bifurcating Vessels

Affiliations

In Vitro Study of Particle Transport in Successively Bifurcating Vessels

Omid Amili et al. Ann Biomed Eng. 2019 Nov.

Abstract

To reach a predictive understanding of how particles travel through bifurcating vessels is of paramount importance in many biomedical settings, including embolization, thromboembolism, and drug delivery. Here we utilize an in vitro model in which solid particles are injected through a rigid vessel that symmetrically bifurcates in successive branching generations. The geometric proportion and fluid dynamics parameters are relevant to the liver embolization. The volumetric flow field is reconstructed via phase-contrast magnetic resonance imaging, from which the particle trajectories are calculated for a range of size and density using the particle equation of motion. The method is validated by directly tracking the injected particles via optical imaging. The results indicate that, opposite to the common assumption, the particles distribution is fundamentally different from the volumetric flow partition. In fact, the amount of delivered particles vary substantially between adjacent branches even when the flow is uniformly distributed. This is not due to the inertia of the particles, nor to gravity. The particle distribution is rather rooted in their different pathways, which in turn are linked to their release origin along the main vessel cross-section. Therefore, the tree geometry and the associated flow streamlines are the prime determinant of the particle fate, while local changes of volumetric flow rate to selected branches do not generally produce proportional changes of particle delivery.

Keywords: Bifurcating vessels; Lagrangian particle tracking; PC-MRI; Particle embolization.