Meta-Analysis
. 2019 Oct;29(7):1383-1393.
doi: 10.1007/s00590-019-02460-0. Epub 2019 Jun 5.

Sliding hip screws versus cancellous screws for femoral neck fractures: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Sliding hip screws versus cancellous screws for femoral neck fractures: a systematic review and meta-analysis

Mohamed S A Shehata et al. Eur J Orthop Surg Traumatol. 2019 Oct.

Abstract

Purpose: Both sliding hip screws (SHS) and cancellous screws are used in the surgical management of intracapsular femoral neck fracture. However, there is paucity of information as to which is the superior treatment modality. We performed this systematic review and meta-analysis study to compare the clinical outcomes of SHS and cancellous screws for the treatment of femoral neck fractures in adult patients.

Methods: We searched PubMed, Scopus, Web of Science, and Cochrane CENTRAL, up to December 2017. Randomized controlled trials (RCTs) directly comparing the clinical outcomes of SHS and cancellous screws for femoral neck fractures were retrieved with no language or publication year restrictions. Data retrieved included operative details, nonunion rate, avascular necrosis, reoperation, infection and mortality, hip pain, functional hip scores, and medical complications. These were pooled as risk ratio or mean difference (MD) with their corresponding 95% confidence interval (CI). Heterogeneity was assessed by Chi-square test.

Results: Ten RCTs involving 1934 patients were included in the final analysis. The pooled estimate showed that the SHS group was associated with more intraoperative blood loss (MD = 110.01 ml, 95% CI [52.42, 167.60], p = 0.00002) than the cancellous screws. There was no significant difference in terms of operative time, postoperative hip function, nonunion, avascular necrosis, reoperation rate, infection, fracture healing, hip pain, medical complications, and mortality rate.

Conclusion: Based on our study, the cancellous screws group was associated with less intraoperative blood loss in comparison with the SHS group. No other significant differences were found between the two interventions.

Keywords: Cancellous screws; Femoral neck fractures; Internal fixation; Sliding hip screws.

PubMed Disclaimer

References

    1. Chin J Traumatol. 2016 Aug 1;19(4):209-12 - PubMed
    1. Bone Joint J. 2018 Apr 1;100-B(4):443-449 - PubMed
    1. J Oslo City Hosp. 1986 May-Jun;36(5-6):55-61 - PubMed
    1. Acta Orthop. 2019 Feb;90(1):21-25 - PubMed
    1. Osteoporos Int. 1997;7(5):407-13 - PubMed

LinkOut - more resources