. 2019 Jun 3;82(5):389-393.
doi: 10.5935/0004-2749.20190072.

Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique

Affiliations
Free article

Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique

Kamil Yavuzer et al. Arq Bras Oftalmol. .
Free article

Abstract

Purpose: To evaluate the efficacy and safety of the modified Yamane technique with sutureless transconjunctival intrascleral intraocular lens fixation.

Methods: Sutureless transconjunctival intrascleral haptic fixated intraocular lens implantation was performed in patients with aphakia and dislocated intraocular lenses. A clear corneal incision (2.8 mm) was made into the temporal quadrant and a three-piece intraocular lens was implanted into the anterior chamber. The haptics of the intraocular lens were externalized with a 27 G needle via transconjunctival scleral tunnels at the 6 and 12 o'clock positions. The transconjunctival scleral tunnels were prepared to conform to the haptic position and curvature. The site of the scleral tunnels was 2mm from the limbus with a length of 2 mm in the sclera and was aimed at the end of the posterior chamber. The tips of the haptics were cauterized to create a terminal knob. The haptics were pushed back and the knobs were implanted into the scleral tunnels.

Results: The study cohort included 21 patients with unilateral aphakia and dislocated intraocular lenses. All patients were examined postoperatively and at postoperative day 1, day 7, month 1, and month 3. All examinations revealed formation of the anterior chamber and well-centralized intraocular lenses. No haptic-related complications of exposure, foreign body sensation, or discomfort were observed.

Conclusion: Sutureless transconjunctival intrascleral haptic fixated intraocular lensimplantation is an effective, safe, and practical surgical alternative. This technique was superior to the Yamane method with regard to comfort and surgical duration. Further studies with longer follow-up evaluations are warranted to verify long-term complications.

PubMed Disclaimer