Microsleep as a marker of sleepiness in obstructive sleep apnea patients
- PMID: 31180173
- DOI: 10.1111/jsr.12882
Microsleep as a marker of sleepiness in obstructive sleep apnea patients
Abstract
We hypothesized that: (a) the presence of microsleep (MS) during a Maintenance Wakefulness Test (MWT) trial may represent a reliable marker of sleepiness in obstructive sleep apnea (OSA) patients; (b) the number of MSs will be higher in sleepy versus non-sleepy patients with a borderline MWT mean sleep latency; and (c) scoring MS during MWT analysis may help physicians to recognize patients with a higher degree of sleepiness. We analysed the MWT data of 112 treatment-naïve OSA patients: 20 with short sleep latency (SL, sleep latency <12.8 min), 43 with borderline latency (BL, sleep latency between 12.8 and 32.6 min) and 49 with normal latency (NL, sleep latency >32.6 min). Microsleep was identified in all SL, in 42 BL and in 18 NL patients, with a median latency of 5.6 min. Accordingly, patients were classified into two subgroups: group A (n = 43) with microsleep latency <5.6 min and group B (n = 69) with microsleep latency >5.6 min when present. The mean sleep latency in the MWT was 14.5 ± 7.5 min in group A and 34.6 ± 7.4 min in group B (p < 0.0001). The number of microsleep episodes during each MWT trial was higher in group A than in group B. Sleep latency survival curves demonstrated different patterns of sleep latency in these groups (log-rank test <0.0001). This finding was confirmed in a Cox proportional hazard analysis: the presence of a mean MS latency <5.6 min is associated with an increasing risk of falling asleep during the MWT (RR, 1.93; 95 CI 1.04-3.6; p = 0.03). We conclude that the detection of microsleep may help in discriminating OSA patients with and without daytime vigilance impairment.
Keywords: COPD; OSA; excessive daytime sleepiness; hypoxia; sleep apnea; sleepiness.
© 2019 European Sleep Research Society.
Similar articles
-
Microsleep versus Sleep Onset Latency during Maintenance Wakefulness Tests: Which One Is the Best Marker of Sleepiness?Clocks Sleep. 2021 Apr 30;3(2):259-273. doi: 10.3390/clockssleep3020016. Clocks Sleep. 2021. PMID: 33946265 Free PMC article.
-
Microsleep assessment enhances interpretation of the Maintenance of Wakefulness Test.J Clin Sleep Med. 2021 Aug 1;17(8):1571-1578. doi: 10.5664/jcsm.9250. J Clin Sleep Med. 2021. PMID: 33729911 Free PMC article.
-
Automatic slow eye movement (SEM) detection of sleep onset in patients with obstructive sleep apnea syndrome (OSAS): comparison between multiple sleep latency test (MSLT) and maintenance of wakefulness test (MWT).Sleep Med. 2010 Mar;11(3):253-7. doi: 10.1016/j.sleep.2009.05.020. Epub 2010 Feb 16. Sleep Med. 2010. PMID: 20163984 Clinical Trial.
-
Objective measures of sleepiness and wakefulness: application to the real world?J Clin Neurophysiol. 2006 Feb;23(1):39-49. doi: 10.1097/01.wnp.0000190416.62482.42. J Clin Neurophysiol. 2006. PMID: 16514350 Review.
-
A normative study of the maintenance of wakefulness test (MWT).Electroencephalogr Clin Neurophysiol. 1997 Nov;103(5):554-62. doi: 10.1016/s0013-4694(97)00010-2. Electroencephalogr Clin Neurophysiol. 1997. PMID: 9402886 Free PMC article. Review.
Cited by
-
Network characteristics of comorbid symptoms in alcohol use disorder.Ann Med. 2025 Dec;57(1):2446691. doi: 10.1080/07853890.2024.2446691. Epub 2025 Jan 13. Ann Med. 2025. PMID: 39801256 Free PMC article.
-
The role of microsleeps to estimate sleepiness at the wheel and near-miss accidents in obstructive sleep apnea.J Clin Sleep Med. 2025 Feb 1;21(2):287-295. doi: 10.5664/jcsm.11376. J Clin Sleep Med. 2025. PMID: 39347562
-
Novel biomarkers derived from the Maintenance of Wakefulness Test as predictors of sleepiness and response to treatment.Sleep. 2024 Dec 11;47(12):zsae148. doi: 10.1093/sleep/zsae148. Sleep. 2024. PMID: 38954525 Free PMC article. Clinical Trial.
-
Microsleep versus Sleep Onset Latency during Maintenance Wakefulness Tests: Which One Is the Best Marker of Sleepiness?Clocks Sleep. 2021 Apr 30;3(2):259-273. doi: 10.3390/clockssleep3020016. Clocks Sleep. 2021. PMID: 33946265 Free PMC article.
-
Automatically Detected Microsleep Episodes in the Fitness-to-Drive Assessment.Front Neurosci. 2020 Jan 23;14:8. doi: 10.3389/fnins.2020.00008. eCollection 2020. Front Neurosci. 2020. PMID: 32038155 Free PMC article.
References
REFERENCES
-
- American Academy of Sleep Medicine (2014). International classification of sleep disorders, 3rd edn. Darien, Illinois: American Academy of Sleep Medicine.
-
- Arand, D., Bonnet, M., Hurwitz, T., Mitler, M., Rosa, R., & Sangal, R. B. (2005). The clinical use of the MSLT and MWT. Sleep, 28(1), 123-144. https://doi.org/10.1093/sleep/28.1.123
-
- Aurora, N. R., Caffo, B., Craniceanu, C., & Punjabi, N. M. (2011). Correlating subjective and objective sleepiness: Revisiting the association using survival analysis. Sleep, 34, 1707-1714. https://doi.org/10.5665/sleep.1442
-
- Banks, S., Marnes, M., Tarquinio, N., Pierce, R. J., Lack, L. C., & McEvoy, R. D. (2004). The maintenance of wakefulness test in normal healthy subjects. Sleep, 27, 799-802.
-
- Bedard, M. A., Montplaisir, J., Richer, F., & Malo, J. (1991). Nocturnal hypoxemia as a determinant of vigilance impairment in sleep apnea syndrome. Chest, 100(2), 367-370. https://doi.org/10.1378/chest.100.2.367
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources