Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Oct;17(5):619-626.
doi: 10.6002/ect.2018.0331. Epub 2019 Jun 10.

Impact of Arteriovenous Fistula on Cardiac Size and Function in Kidney Transplant Recipients: A Retrospective Evaluation of 5-Year Echocardiographic Outcome

Affiliations
Free article

Impact of Arteriovenous Fistula on Cardiac Size and Function in Kidney Transplant Recipients: A Retrospective Evaluation of 5-Year Echocardiographic Outcome

Marios Papasotiriou et al. Exp Clin Transplant. 2019 Oct.
Free article

Abstract

Objectives: The effect of a functioning arteriovenous fistula on cardiac function in kidney transplant recipients has not been thoroughly investigated.

Materials and methods: We retrospectively evaluated cardiac function in 99 renal transplant recipients using transthoracic echocardiography, with available follow-up at baseline and 2 and 5 years posttransplant. Patients were divided into 2 groups: a control group (n = 47) with no functioning arteriovenous fistula immediately after transplant and an arteriovenous fistula group (n = 52) with a functioning arteriovenous fistula for at least 5 years after transplant. Left ventricular ejection fraction, diastolic thickness of the interventricular septum, and left ventricular end-diastolic diameter were assessed.

Results: In our study, patients (62.6% men, 7.1% with diabetes, mean age of 55.6 ± 11.5 years), we observed no significant differences with respect to baseline left ventricular ejection fraction and interventricular septum; however, in the arteriovenous fistula group, baseline left ventricular end-diastolic diameter was marginally higher than that shown in the control group (50.6 ± 5.4 vs 48.6 ± 4.4 mm; P = .054). In multivariate analysis, functioning fistula and peripheral arterial disease were negatively associated with left ventricular ejection fraction at 5 years posttransplant, whereas baseline left ventricular ejection fraction had a minimal positive effect: B (95% confidence interval) of -2.186 (-4.312 to -0.061) (P = .044), -5.304 (-9.686 to -0.922) (P = .018), and 0.247 (0.047 to 0.446) (P = .016), respectively. Functioning fistula also emerged as associated with larger left ventricular end-diastolic diameter at 2 and 5 years posttransplant: B (95% confidence interval) of 3.047 (1.470-4.625) (P < .001) and 2.122 (0.406-3.838) (P = .016), respectively.

Conclusions: Maintenance of a functioning fistula in kidney transplant recipients may be associated with adverse long-term effects on left ventricular ejection fraction and left ventricular end-diastolic diameter.

PubMed Disclaimer

LinkOut - more resources