Evaluation of dressing regimens for prevention of infection with peripheral intravenous catheters. Gauze, a transparent polyurethane dressing, and an iodophor-transparent dressing
- PMID: 3118061
Evaluation of dressing regimens for prevention of infection with peripheral intravenous catheters. Gauze, a transparent polyurethane dressing, and an iodophor-transparent dressing
Abstract
Four dressing regimens for peripheral venous catheters were studied in a prospective randomized clinical trial with 2088 Teflon catheters: (1) sterile gauze, replaced every other day, and three dressings left on for the lifetime of the catheter; (2) gauze; (3) a transparent polyurethane dressing; and (4) an iodophor-transparent dressing. The four dressings provided comparable coverage, except moisture accumulated more frequently under the transparent dressings (26% to 28% vs 20% to 21%). Cutaneous colonization under the dressing was low level and comparable with all four dressings (range, 10(0.58) to 10(0.70) colony-forming units). The rate of local catheter-related infection (greater than or equal to 15 colony-forming units) was also low and did not differ significantly (range, 4.6% to 5.9%); no catheter caused bacteremia. Stepwise logistic multivariate analysis showed cutaneous colonization of the insertion site (relative risk [RR] of infection, 3.86), contamination of the catheter hub (RR, 3.78), moisture under the dressing (RR, 2.48), and prolonged catheterization (RR, 1.75) to be significant risk factors for catheter-related infection. These data indicate that it is not cost-effective to redress peripheral venous catheters at periodic intervals; for most patients, either sterile gauze or a transparent dressing can be used and left on until the catheter is removed.
Similar articles
-
A prospective, randomized trial of gauze and two polyurethane dressings for site care of pulmonary artery catheters: implications for catheter management.Crit Care Med. 1994 Nov;22(11):1729-37. Crit Care Med. 1994. PMID: 7956275 Clinical Trial.
-
Transparent polyurethane film as an intravenous catheter dressing. A meta-analysis of the infection risks.JAMA. 1992 Apr 15;267(15):2072-6. JAMA. 1992. PMID: 1532429
-
A comparison of transparent polyurethane and dry gauze dressings for peripheral i.v. catheter sites: rates of phlebitis, infiltration, and dislodgment by patients.Am J Crit Care. 1997 Sep;6(5):377-81. Am J Crit Care. 1997. PMID: 9283675 Clinical Trial.
-
Dressings for the central venous catheter to prevent infection in patients undergoing hematopoietic stem cell transplantation: a systematic review and meta-analysis.Support Care Cancer. 2020 Feb;28(2):425-438. doi: 10.1007/s00520-019-05065-9. Epub 2019 Sep 6. Support Care Cancer. 2020. PMID: 31493134
-
The use of gauze versus transparent dressings for peripheral intravenous catheter sites.Nurs Clin North Am. 1995 Sep;30(3):495-506. Nurs Clin North Am. 1995. PMID: 7567574 Review.
Cited by
-
Prospective multicenter study of vascular-catheter-related complications and risk factors for positive central-catheter cultures in intensive care unit patients.J Clin Microbiol. 1990 Nov;28(11):2520-5. doi: 10.1128/jcm.28.11.2520-2525.1990. J Clin Microbiol. 1990. PMID: 2254429 Free PMC article. Clinical Trial.
-
Skin disinfection in preterm infants.Arch Dis Child. 1993 Sep;69(3 Spec No):312-6. doi: 10.1136/adc.69.3_spec_no.312. Arch Dis Child. 1993. PMID: 8215573 Free PMC article.
-
Intravenous fluid therapy in calves.Vet Clin North Am Food Anim Pract. 1990 Mar;6(1):77-101. doi: 10.1016/s0749-0720(15)30896-3. Vet Clin North Am Food Anim Pract. 1990. PMID: 2178742 Free PMC article. Review.
-
Access technique and its problems in parenteral nutrition - Guidelines on Parenteral Nutrition, Chapter 9.Ger Med Sci. 2009 Nov 18;7:Doc19. doi: 10.3205/000078. Ger Med Sci. 2009. PMID: 20049083 Free PMC article. Review.
-
Central venous Access device SeCurement And Dressing Effectiveness for peripherally inserted central catheters in adult acute hospital patients (CASCADE): a pilot randomised controlled trial.Trials. 2017 Oct 4;18(1):458. doi: 10.1186/s13063-017-2207-x. Trials. 2017. PMID: 28978332 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical