Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Dec;90(4):487-496.
doi: 10.1080/02701367.2019.1620911. Epub 2019 Jun 11.

Reliability of a Novel Badminton Intermittent Exercise Protocol

Affiliations

Reliability of a Novel Badminton Intermittent Exercise Protocol

Jingyi Shannon Chia et al. Res Q Exerc Sport. 2019 Dec.

Abstract

Purpose: Badminton is a sport characterized by high-intensity activity interspersed with short rests requiring specific physiological fitness, skills and game tactics. This study aimed to develop, describe and establish the reliability of a novel badminton intermittent exercise protocol, to simulate singles match-play (Part A) and assess match-fitness (Part B). Method: Twelve well-trained male badminton players performed a two-part protocol, mimicking the demands and activity of match-play, on two occasions with at least 72-h recovery. Part A imitated match-play and consisted of 40 stages alternating between 20 s work - receiving shuttlecocks from a launcher and ghosting (simulated) actions - and 40 s rest. Part B was an open-ended period, challenging match-fitness, designed to exhaust participants within 10 min. Physiological responses (heart rate, blood lactate and ratings of perceived exertion) (Part A and B) and time to exhaustion (Part B) were determined both times. Results: There were no differences in performance and physiological responses between trials (p > .05). The protocol demonstrated excellent reliability (intraclass correlation coefficient > 0.89) for all variables. Time to exhaustion (Part B) was 198 ± 98 s and 194 ± 82 s, respectively. Mean (Part A) and peak (Part B) heart rates were 166 ± 9; 191 ± 8 b∙min-1 and 166 ± 9; 191 ± 7 b∙min-1 and blood lactate concentrations (Part B) 11.8 ± 2.3 and 11.5 ± 2.1 mmol∙l-1 for trials 1 and 2, respectively. Conclusion: The protocol reliably induces match-like responses and can be used to assess match-fitness for training/research purposes.

Keywords: Fitness; performance; representative; singles; sport-specific.

PubMed Disclaimer