Ultrasound-Guided Biceps Tendon Sheath Injection: Spectrum of Preprocedure Appearances
- PMID: 31187487
- DOI: 10.1002/jum.15062
Ultrasound-Guided Biceps Tendon Sheath Injection: Spectrum of Preprocedure Appearances
Abstract
Objectives: To determine the frequency of ultrasound (US) appearances of the extra-articular long head of the proximal biceps tendon in patients referred for US-guided biceps tendon sheath injections.
Methods: We reviewed our US-guided biceps tendon sheath injections between January 2015 and December 2017, noting the appearance of the biceps tendon and sheath, as well as the needle size used, and what was injected. Clinical electronic medical records were also reviewed to determine safety and patients' responses.
Results: A total of 300 US-guided biceps tendon sheath injections were performed for anterior shoulder pain. Preliminary US evaluations revealed that 129 of 300 (43%) patients had a normal US appearance of the biceps tendon; 110 (36.6%) had tendinosis; 13 (4.3%) had tenosynovitis; 31 (10.3%) had both tendinosis and tenosynovitis; 8 (2.7%) had a biceps tendon tear; and 9 (3%) had a history of a tenodesis. Of 81 patients who had pain relief after the injection, 41 had a normal tendon appearance on US, and 40 had an abnormal US appearance.
Conclusions: A large minority of patients with anterior shoulder pain clinically suspected to be due to the biceps tendon have a normal-appearing tendon and sheath. This should not dissuade the operator from performing the procedure.
Keywords: biceps tendon; guidance; injection; steroid; ultrasound.
© 2019 by the American Institute of Ultrasound in Medicine.
Comment in
-
The Biceps Long-Head Tendon: An Overlooked Pain Origin for Ultrasound-Guided Injection.J Ultrasound Med. 2020 Feb;39(2):409-410. doi: 10.1002/jum.15109. Epub 2019 Aug 8. J Ultrasound Med. 2020. PMID: 31392752 No abstract available.
References
-
- Ding DY, Garofolo G, Lowe D, Strauss EJ, Jazrawi LM. The biceps tendon: from proximal to distal-AAOS exhibit selection. J Bone Joint Surg Am 2014; 96:e176.
-
- Churgay CA. Diagnosis and treatment of biceps tendinitis and tendinosis. Am Fam Physician 2009; 80:470-476.
-
- Hashiuchi T, Sakurai G, Morimoto M, Komei T, Takakura Y, Tanaka Y. Accuracy of the biceps tendon sheath injection: ultrasound-guided or unguided injection? A randomized controlled trial. J Shoulder Elbow Surg 2011; 20:1069-1073.
-
- Petscavage-Thomas J, Gustas C. Comparison of ultrasound-guided to fluoroscopy-guided biceps tendon sheath therapeutic injection. J Ultrasound Med 2016; 35:2217-2221.
-
- Blankenbaker DG, De Smet AA, Keene JS. Sonography of the iliopsoas tendon and injection of the iliopsoas bursa for diagnosis and management of the painful snapping hip. Skeletal Radiol 2006; 35:565-571.
MeSH terms
LinkOut - more resources
Full Text Sources
