Evaluation of the Clinitek®, a point-of-care urinalysis system for the measurement of clinically significant urinary metabolites and detection of haematuria in Schistosoma haematobium infected children in southern Côte d'Ivoire
- PMID: 31196145
- PMCID: PMC6567640
- DOI: 10.1186/s13071-019-3555-z
Evaluation of the Clinitek®, a point-of-care urinalysis system for the measurement of clinically significant urinary metabolites and detection of haematuria in Schistosoma haematobium infected children in southern Côte d'Ivoire
Abstract
Background: Urinary schistosomiasis, caused by Schistosoma haematobium, remains a significant public health problem worldwide, despite years of efforts to control it. Haematuria is one of the notable indirect indicators of S. haematobium infection and is commonly assessed along with other routine screens using a urinary dipstick test. A portable "field friendly" electronic analyser would offer an automated and thus more objective read-out compared to visual-read dipstick methods.
Methods: Within the framework of a Phase 2 praziquantel dose finding study in preschool- and school-aged children infected with S. haematobium, in southern Côte d'Ivoire, we compared a visual-read of the urine dipstick strips (Multistix PRO, Siemens Healthcare Diagnostics) to an automated reader (CLINITEK Status+ analyser™ Siemens Healthcare Diagnostics). Urine samples were collected from 148 pre-school aged and 152 school-aged children for urinalysis. Values were compared using a linear weighted kappa statistic and Bland-Altman analysis.
Results: A very good correlation between the two methods for nitrites and haematuria was observed (κ coefficient of 0.88 and 0.82, respectively), while a good correlation was observed for leukocytes (κ coefficient of 0.63) A moderate to fair correlation was calculated (κ coefficient ≤ 0.6) for all other parameters. When the results were stratified according to infection intensity, the agreements were stronger from the high infection intensity sample measurements, for most of the parameters.
Conclusion: Our results demonstrate the device's utility in detecting haematuria and nitrites but underline the need for further development of this tool in order to improve its performance in the field.
Keywords: Electronic analyser; Haematuria; Schistosoma haematobium; Urinalysis; Urinary dip-stick.
Conflict of interest statement
The authors declare that they have no competing interests.
Figures

Similar articles
-
Evaluation of the effectiveness of dipstick haematuria and proteinuria in screening Schistosoma haematobium infection among school children in upper Egypt.J Egypt Public Health Assoc. 1996;71(5-6):353-67. J Egypt Public Health Assoc. 1996. PMID: 17214186
-
Urogenital schistosomiasis prevalence and diagnostic performance of urine filtration and urinalysis reagent strip in schoolchildren, Ethiopia.PLoS One. 2022 Jul 25;17(7):e0271569. doi: 10.1371/journal.pone.0271569. eCollection 2022. PLoS One. 2022. PMID: 35877771 Free PMC article.
-
Interrupting seasonal transmission of Schistosoma haematobium and control of soil-transmitted helminthiasis in northern and central Côte d'Ivoire: a SCORE study protocol.BMC Public Health. 2018 Jan 29;18(1):186. doi: 10.1186/s12889-018-5044-2. BMC Public Health. 2018. PMID: 29378542 Free PMC article. Clinical Trial.
-
The usefulness of indirect diagnostic tests for Schistosoma haematobium infection after repeated rounds of mass treatment with praziquantel in Mpwapwa and Chakechake districts in Tanzania.Int J Infect Dis. 2020 Jan;90:132-137. doi: 10.1016/j.ijid.2019.10.031. Epub 2019 Nov 4. Int J Infect Dis. 2020. PMID: 31693938
-
Meta-analysis of urine heme dipstick diagnosis of Schistosoma haematobium infection, including low-prevalence and previously-treated populations.PLoS Negl Trop Dis. 2013 Sep 12;7(9):e2431. doi: 10.1371/journal.pntd.0002431. eCollection 2013. PLoS Negl Trop Dis. 2013. PMID: 24069486 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical