. 2019 Jun 13;186(7):432.
doi: 10.1007/s00604-019-3482-x.

Magnetic fiber headspace solid-phase microextraction coupled to GC-MS for the extraction and quantitation of polycyclic aromatic hydrocarbons

Affiliations

Magnetic fiber headspace solid-phase microextraction coupled to GC-MS for the extraction and quantitation of polycyclic aromatic hydrocarbons

Fahimeh Rasolzadeh et al. Mikrochim Acta. .

Abstract

A technique was developed for magnetic fiber headspace-solid phase microextraction (MF-HS-SPME) of polycyclic aromatic hydrocarbons (PAHs). The efficiency of the extraction of a steel SPME fiber coated with an aminoethyl-functionalized SBA-15 (Santa Barbara Amorphous 15; a nanoporous sorbent) is substantially improved after its magnetization during HS-SPME. The effects of magnetic field strength, extraction temperature, extraction time, moisture content of the sample, desorption time and desorption temperature were optimized using a simplex method. The application of a moderately strong magnetic field to the fiber results in up to 135% increase in the extraction efficiency and wider linear dynamic ranges. The PAHs (specifically naphthalene, acenaphthene, fluorene, anthracene, phenanthrene, fluoranthene and pyrene) were then quantified by GC-MS analysis. Comparison of an electromagnet and a permanent magnet indicated the superior effect of the permanent magnet for the target analytes due to the Ohmic heating of the magnetic coil and its negative effect on the extraction of some of the PAHs. The limits of detections of the PAHs are between 0.17 to 0.57 ng g-1 by using the electromagnet, and between 0.10 and 0.32 ng g-1 for the permanent magnet. Relative standard deviations of 2.9 to 7.6% were obtained for six replicated analyses of the analytes. The method was applied to some polluted soil samples, and satisfactory results were obtained. Graphical abstract Schematic representation of the designed magnetic fiber headspace solid-phase microextraction (MF-HS-SPME) system using (a) an electromagnet, (b) a pair of permanent disc magnets.

Keywords: Magnetism; Nanoporous sorbent; Polycyclic aromatic hydrocarbons; Soil; Solid-phase microextraction.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Mikrochim Acta. 2018 Jun 27;185(7):342 - PubMed
    1. Anal Chem. 2010 May 15;82(10):4020-6 - PubMed
    1. J Chromatogr Sci. 2018 Oct 1;56(9):771-778 - PubMed
    1. Molecules. 2018 May 14;23(5): - PubMed
    1. Anal Chim Acta. 2016 Sep 21;937:69-79 - PubMed

LinkOut - more resources