. 2019 Sep;103(3):225-233.
doi: 10.1111/ejh.13277. Epub 2019 Jul 2.

Pathogenic heparin-induced thrombocytopenia and thrombosis (HIT) antibodies determined by rapid functional flow cytometry

Affiliations

Pathogenic heparin-induced thrombocytopenia and thrombosis (HIT) antibodies determined by rapid functional flow cytometry

Michal Cipok et al. Eur J Haematol. 2019 Sep.

Abstract

Objectives: Reliable diagnosis of heparin-induced thrombocytopenia and thrombosis (HIT) is mandatory for patient management, yet prompt determination of pathogenic antibodies remains an unmet clinical challenge. Common immunoassays carry inherent limitations and functional assays which detect antibody-mediated platelet activation are not usually readily available to routine laboratories, especially the serotonin release assay (SRA), being technically demanding, time consuming, and requires high level expertise. To overcome some of these limitations, we have developed a practical functional flow cytometric assay (FCA) for routine clinical use.

Methods: A simple FCA is described which avoids platelet manipulation, is highly specific and sensitive compared with SRA, and provides rapid results.

Results: Of the 650 consecutive samples, from HIT-suspected patients, 99 (15.3%) were positive by the PaGIA Heparin/PF4 immunoassay and 31 (4.8%) by FCA. Average platelet activation was 11-fold higher in PaGIA+/FCA+ vs PaGIA-/FCA- samples. Of 21 SRA-positive samples, 19 were FCA-positive (relative sensitivity 90.5%), and of 42 SRA-negative samples, 40 were FCA-negative (relative specificity 95.2%). The FCA showed significantly higher correlation with the clinical presentation of HIT (4Ts score) performed on 182 patients, compared with PaGIA Heparin/PF4 (ROC-plot analysis, AUC 0.93 vs 0.63, P < 0.001). At a 92% sensitivity, the assay specificity was 96%.

Conclusions: The present FCA is practical for routine testing, providing prompt reliable results for initial diagnosis and confirmation, to effectively assist in HIT patient management.

Keywords: antibodies; flow cytometry; heparin-induced; thrombocytopenia; thrombosis.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. Huynh A, Arnold DM, Kelton JG, et al. Characterization of platelet factor 4 amino acids that bind pathogenic antibodies in heparin-induced thrombocytopenia. J Thromb Haemost. 2019;17(2):389-399.
    1. Chong BH. Heparin-induced thrombocytopenia. Blood Rev. 1988;2(2):108-114.
    1. Greinacher A, Farner B, Kroll H, Kohlmann T, Warkentin TE, Eichler P. Clinical features of heparin-induced thrombocytopenia including risk factors for thrombosis. A retrospective analysis of 408 patients. Thromb Haemost. 2005;94(1):132-135.
    1. Kelton JG, Sheridan D, Santos A, et al. Heparin-induced thrombocytopenia: laboratory studies. Blood. 1988;72(3):925-930.
    1. Sheridan D, Carter C, Kelton JG. A diagnostic test for heparin-induced thrombocytopenia. Blood. 1986;67(1):27-30.

MeSH terms

LinkOut - more resources