Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Jun;39(3):426-430.
doi: 10.1007/s11596-019-2054-y. Epub 2019 Jun 17.

Outcome Assessment of Z-shaped Osteotomy in the Management of Humeral Shaft Nonunion Secondary to Failed Plate Osteosynthesis

Affiliations

Outcome Assessment of Z-shaped Osteotomy in the Management of Humeral Shaft Nonunion Secondary to Failed Plate Osteosynthesis

Dong Chen et al. Curr Med Sci. 2019 Jun.

Abstract

Restoration of fracture alignment by osteotomy is crucial for the management of humeral nonunion. In the present study, we introduced a new way of osteotomy (Z-shaped) in treating humeral shaft nonunion secondary to failed plate osteosynthesis. Clinical data of 24 patients with humeral shaft nonunion following implant failure (from 2010 to 2014) were retrospectively evaluated. These patients underwent Z-shaped osteotomy in revision surgery after the initial surgery, plate osteosynthesis, was failed. Outcomes were evaluated using visual analogue scale (VAS) and Constant and Murley score. Repeated analysis of variance (ANOVA) was used for statistical analysis. Patients were followed up for a minimum of 24 months (26.83±4.33 months). The operative time was 102.33±10.16 min, and hospital stay averaged 9.75±2.13 days. All patients achieved clinical union at the latest follow-up. Complications included radial palsy (n=1) and superficial wound infection (n=1). The postoperative VAS scores decreased significantly compared to preoperative score (F=257.99, P<0.01). Constant and Murley score increased and reached 81.33±0.95 at 24 months' follow-up (F=247.35, P<0.01). Among all the cases, 15 cases were graded as "excellent", and 9 as "good". In conclusion, Z-shaped osteotomy was easy to perform, and it provided additional medial support with more bone contact areas. Revision surgery using locking plate and Z-shaped osteotomy achieved high union rate and improved functional outcome. It was a reasonable and safe option for treating humeral nonunion following implant failure.

Keywords: Z-shaped osteotomy; humeral shaft nonunion; implant failure.

PubMed Disclaimer

Similar articles

References

    1. Am J Orthop (Belle Mead NJ). 2000 Jan;29(1):45-7 - PubMed
    1. J Orthop Res. 2002 May;20(3):593-9 - PubMed
    1. Acta Orthop Scand. 2002 Jun;73(3):273-6 - PubMed
    1. J Am Acad Orthop Surg. 2003 Jan-Feb;11(1):48-59 - PubMed
    1. Clin Orthop Relat Res. 2004 Feb;(419):46-50 - PubMed

MeSH terms

LinkOut - more resources