Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Jul:234:101-109.
doi: 10.1016/j.vetmic.2019.05.024. Epub 2019 May 31.

Diagnostic accuracy of phenotypic assays for determining antimicrobial resistance status in Staphylococcus pseudintermedius isolates from canine clinical cases

Affiliations

Diagnostic accuracy of phenotypic assays for determining antimicrobial resistance status in Staphylococcus pseudintermedius isolates from canine clinical cases

Skye Badger et al. Vet Microbiol. 2019 Jul.

Abstract

This study evaluated the diagnostic test accuracy of disc diffusion relative to broth-microdilution for clinical Staphylococcus pseudintermedius isolated from dogs in Australia (n = 614). Accuracy of disc diffusion and broth-microdilution for oxacillin relative to mecA real-time PCR was also assessed. Each isolate had paired minimum inhibitory concentration and zone diameter values for ten antimicrobial agents. Data was dichotomised using Clinical and Laboratory Standards Institute susceptible and resistant clinical breakpoints. Test accuracy was reported using relative diagnostic sensitivity (RSe), specificity (RSp), likelihood ratio pairs, diagnostic odds ratio, and area-under-the receiver-operating characteristic (ROC AUC) analysis. Disc diffusion was found to have high test accuracy for most antimicrobials (ROC AUC range: 0.96 - 0.99) except rifampicin (ROC AUC = 0.80). The RSp of disc diffusion was high for all antimicrobials (range, 97.1%-100%). However, RSe was considerably variable (range, 35.7%-98.8%), particularly for amoxicillin-clavulanic acid (51.5%, 95% CI, 38.9%, 64.0%), cefoxitin (35.7%, 95% CI, 12.8%, 64.9%), and cephalothin (43.6%, 95% CI, 27.8%, 60.4%). When disc diffusion and broth-microdilution were compared to mecA real-time PCR, the overall accuracy of both assays was similar (ROC AUC, 0.99 respectively). However, the RSe for broth-microdilution (96.1%, 95% CI, 88.9%, 99.2%) was significantly higher than for disc diffusion (86.8%, 95% CI, 77.1%, 93.5%) (McNemars mid-p value 0.01). Overall, these findings demonstrate that for most antimicrobials, disc diffusion performed according to CLSI guidelines can be used to differentiate clinical S. pseudintermedius isolates that might otherwise be assessed by broth-microdilution, provided consideration is given to the performance estimates reported here.

Keywords: Accuracy; Antimicrobial resistance; Broth-microdilution; Disc diffusion; ROC; Surveillance.

PubMed Disclaimer

MeSH terms

LinkOut - more resources