Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Jan;14(1):77-82.
doi: 10.1177/1932296819856360. Epub 2019 Jun 19.

Cellular-Enabled Glucometers and Maternal Glucose Control: A Quality Improvement Initiative

Affiliations

Cellular-Enabled Glucometers and Maternal Glucose Control: A Quality Improvement Initiative

Sarah A Wernimont et al. J Diabetes Sci Technol. 2020 Jan.

Abstract

Background: Management of diabetes in pregnancy is burdensome due to self-glucose monitoring, recording, and reporting demands. Cellular-enabled glucometers provide real-time transmission of glucose values independent of internet access and cell phone data plans. We describe a quality improvement (QI) intervention that introduced cellular-enabled glucometers for use during pregnancies complicated by diabetes.

Methods: Our aim was to improve maternal glucose control in a cohort of insulin-requiring pregnant women enrolled in a telemedicine diabetes program. During initial establishment of a QI program, women were offered cellular-enabled glucometers but could elect to keep their standard meter. The primary outcome evaluated was glycosylated hemoglobin A1c (HbA1c) at delivery.

Results: Baseline characteristics including initial HbA1c were similar between women using a standard glucometer (n = 45) and those using a cellular-enabled glucometer (n = 72). Women who used a cellular-enabled glucometer had a lower HbA1c at delivery compared to those using a standard glucometer (5.8% vs 6.3%, P = .03). This improvement was particularly notable for women with poor glucose control (defined as HbA1c >6.5%) at initial obstetric visit. Women with poor glucose control who used a cellular-enabled glucose monitor had significantly lower HbA1c at delivery (6.0% vs 6.8%, P = .03) and greater change from initial visit compared to those using a standard glucometer (-2.6% vs -1.4%, P = .02). No statistically significant differences were detected in tracked neonatal outcomes.

Conclusion: For pregnancies complicated by insulin-requiring diabetes, use of cellular-enabled glucometers as part of a perinatal diabetes program improves glucose control at delivery with timely transmission of accurate values throughout gestation.

Keywords: cellular-enabled glucometer; diabetes; glucometer; pregnancy; quality; telemedicine.

PubMed Disclaimer

Conflict of interest statement

Declaration of Conflicting Interests: The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

Figures

Figure 1.
Figure 1.
Study sample of women enrolled in perinatal diabetes program.

References

    1. American Diabetes Association. Management of diabetes in pregnancy: standards of medical care in diabetes—2019. Diabetes Care. 2019;42:S165-S72. - PubMed
    1. Gestational Diabetes Mellitus. ACOG Practice Bulletin No 190. Washington, DC: American College of Obstetricians and Gynecologists; 2018.
    1. Pregestational Diabetes Mellitus. ACOG Practice Bulletin No 201. Washington, DC: American College of Obstetricians and Gynecologists; 2018.
    1. Carolan M, Gill GK, Steele C. Women’s experiences of factors that facilitate or inhibit gestational diabetes self-management. BMC Pregnancy Childbirth. 2012;12:99. - PMC - PubMed
    1. Youngwanichsetha S, Phumdoung S. Lived experience of blood glucose self-monitoring among pregnant women with gestational diabetes mellitus: a phenomenological research. J Clin Nurs. 2017;26:2915-2921. - PubMed

Publication types