Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Jun 20;14(6):e0218199.
doi: 10.1371/journal.pone.0218199. eCollection 2019.

Graft-size selection and anisometropia reduction in penetrating keratoplasty (PKP)

Affiliations

Graft-size selection and anisometropia reduction in penetrating keratoplasty (PKP)

Ellen H Koo et al. PLoS One. .

Abstract

Purpose: To compare the amount of myopia induced by same-size donor-to-host penetrating keratoplasty with that of the amount of myopia induced by over-sized donor-to-host penetrating keratoplasty.

Setting: Tertiary referral academic center.

Design: Retrospective cohort study.

Methods: Charts from patients who underwent penetrating keratoplasty by the same technique at Bascom Palmer Eye Institute between Nov 1, 2002, and January 1, 2006, were reviewed. The patients underwent optical penetrating keratoplasty using 12 interrupted 10-0 nylon sutures and a 12-bite continuous 10-0 nylon suture by a single surgeon (R.K.F.). The surgical technique used would be considered standard of care at most institutions. The Institutional Review Board, University of Miami Human Subjects Research Office, approved the study protocol. The donor graft was over-sized by 0.25mm in eyes when the intended final refractive target was greater than -1.00 diopters spherical equivalent (SE). The same-size donor graft was used when the intended final refractive target was less than -1.00 diopters SE. The selection of donor graft size was entirely based upon clinical parameters, meaning that the intended final refractive target was determined per each patient's fellow eye refraction, with the intention of reducing anisometropia. All patients received postoperative refraction and corneal topography. These measurements were performed at 6-8 weeks when the initial removal of sutures commenced, then at 6 months, then after completion of selective suture removal, then again at 12 months.

Results: At 12 months, the over-sized group resulted in -1.35 diopters (SD = 2.25) SE of refraction, and the same-size group resulted in -0.14 diopters (SD = 2.42) SE. This approached statistical significance (p = 0.052) in comparison to -1.00 diopters spherical equivalent.

Conclusions: Using a donor graft that is over-sized by 0.25mm results in refraction of -1.00 diopters SE or more of myopia. Using a same-size donor-graft results in refraction of less than -1.00 diopters SE. Therefore, careful graft-size selection can result in a more favorable clinical outcome-namely, reduction in anisometropia-in patients undergoing penetrating keratoplasty.

PubMed Disclaimer

Conflict of interest statement

The authors have declared that no competing interests exist.

Figures

Fig 1
Fig 1. Spherical equivalence in diopters of refraction at 12 months.

Similar articles

References

    1. Price FW, Whitson WE, Collins KS, Marks RG. Five-year corneal graft survival. Arch Ophthalmol. 1993;11:799–805. - PubMed
    1. Vail A, Gore SM, Bradley BA, Easty DL, Rogers CA. Corneal graft survival and visual outcome. A multicenter study. Ophthalmology. 1994;101:120–127. - PubMed
    1. Maeno A, Naor J, Lee HM, et al. Three decades of corneal transplantation: indications and patient characteristics. Cornea 2000;19:7–11. - PubMed
    1. Dursun D, Forster RK, Feuer WJ. Surgical technique for control of postkeratoplasty myopia, astigmatism, and anisometropia. Am J Ophthalmol. 2003;135:807–15. - PubMed
    1. Forster RK. A comparison of two selective interrupted suture removal techniques for control of post keratoplasty astigmatism. Trans Am Ophthalmol Soc. 1997;95:193–214. - PMC - PubMed

Publication types