. 2019 Aug;19(8):e1900109.
doi: 10.1002/mabi.201900109. Epub 2019 Jun 21.

A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum

Affiliations

A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum

Muhammet Aydın et al. Macromol Biosci. 2019 Aug.

Abstract

In this study, an impedimetric immunosensor based on polymer poly(thiophene)-graft-poly(methacrylamide) polymer (P(Thi-g-MAm)) modified indium tin oxide (ITO) electrode is developed for the detection of the Neuron Specific Enolase (NSE) cancer biomarker. First, the P(Thi-g-MAm) polymer is synthesized and coated on the ITO electrode by using a spin-coating technique. P(Thi-g-MAm) polymer acts as an immobilization platform for immobilization of NSE-specific monoclonal antibodies. Anti-NSE antibodies are utilized as biosensing molecules and they bind to the amino groups of P(Thi-g-Mam) polymer via glutaraldehyde cross-linking. Spin-coating technique is employed for bioelectrode fabrication and this technique provides a thin and uniform film on the ITO electrode surface. This bioelectrode fabrication technique is simple and it generates a suitable platform for large-scale loadings of anti-NSE antibodies. This immunosensor exhibits a wide linear detection range from 0.02 to 4 pg mL-1 and with an ultralow detection limit of 6.1 fg mL-1 . It reveals a good long-term stability (after 8 weeks, 78% of its initial activity), an excellent reproducibility (1.29% of relative standard deviation (RSD)), a good repeatability (5.55% of RSD), and a high selectivity. In addition, the developed immunosensor is proposed as a robust diagnostic tool for the clinical detection of NSE and other cancer biomarkers.

Keywords: disposable electrodes; electrochemical impedance spectroscopy; graft polymer; lung cancer; neuron-specific enolase.

PubMed Disclaimer

Publication types

LinkOut - more resources