Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Mar/Apr;31(2):336-339.
doi: 10.1097/SCS.0000000000005587.

Fully Automatic Robot-Assisted Surgery for Mandibular Angle Split Osteotomy

Affiliations

Fully Automatic Robot-Assisted Surgery for Mandibular Angle Split Osteotomy

Mengzhe Sun et al. J Craniofac Surg. 2020 Mar/Apr.

Abstract

With the development of computer-assisted surgery, preoperational design is detailed in software. However, it is still a challenge for surgeons to realize the surgical plan in the craniofacial surgery. Robot-assisted surgery has advantages of high accuracy and stability. It is suitable for the high-stress procedures like drilling, milling, and cutting. This study aims to verify the feasibility for automatic drilling without soft tissues in model test based on an industrial robot platform.This study chose the data from digital laboratory in Shanghai 9th People's Hospital. The mandibular was reconstructed in software and surgical plan was also designed. Then, the coordinate data was input to the robot's software and matrix conversion was calculated by 4 marked points. The trajectory generation was calculated by inverse kinematics for target coordinates and robot coordinates. The model was fixed and calibrated for automatic drilling. At last, the accuracy was calculated by optic scanning instrument.The installment and preparation cost 10 minutes, the drilling procedure cost 12 minutes. The outside position error was (1.71 ± 0.16) mm, the inside position error was (1.37 ± 0.28) mm, the orientation error was (3.04 ± 1.02)°. Additionally, a total of 5 beagles were tested, with an accuracy error of (2.78 ± 1.52) mm. No postoperative complications occurred.This is the first study reported for robot-assisted automatic surgery in craniofacial surgery. The result shows it is possible to realize the automatic drilling procedure under the condition of no interference like soft tissues. With the development of artificial intelligence and machine vision, robot-assisted surgery may help surgeons to fulfill more automatic procedures for craniofacial surgery.

PubMed Disclaimer

References

    1. Deguchi M, Iio Y, Kobayashi K, et al. Angle-splitting ostectomy for reducing the width of the lower face. Plast Reconstr Surg 1997; 99:1831–1839.
    1. Yaxley JW, Coughlin GD, Chambers SK, et al. Robot-assisted laparoscopic prostatectomy versus open radical retropubic prostatectomy: early outcomes from a randomised controlled phase 3 study. Lancet 2016; 388:1057–1066.
    1. Suarez-Ahedo C, Gui C, Martin TJ, et al. Robotic-arm assisted total hip arthroplasty results in smaller acetabular cup size in relation to the femoral head size: a matched-pair controlled study. Hip Int: J Clin Exp Res Hip Pathol Ther 2017; 27:147–152.
    1. Dobbs TD, Cundy O, Samarendra H, et al. A systematic review of the role of robotics in plastic and reconstructive surgery-from inception to the future. Front Surg 2017; 4:66.
    1. Podsedkowski LR, Moll J, Moll M, et al. Are the surgeon's movements repeatable? An analysis of the feasibility and expediency of implementing support procedures guiding the surgical tools and increasing motion accuracy during the performance of stereotypical movements by the surgeon. Polish J Cardiothorac Surg 2014; 11:90–101.

LinkOut - more resources